| SPIP™ v. 5.1.3 (2010-07-01) |
| Basic Module |
 | Fixed wrong interpretation of time units in Omicron Matrix 3.0 files |   |
 | Restored the designed automatic behavior behavior of the "Auto Z calibrate" feature for height histograms |  |
 | Fixed situations where the Color Clip Markers could appear outside the Color Bar range. |  |
 | Fixed various annoying resizing issues regarding display of high X:Y aspect ratio images where a true aspect ratio display is not desired |  |
 | The rigid check for the user having Administrator user rights introduced in version 5.1.2 causing SPIP to refuse running, has been replaced by a warning when the user has a valid dongle based license |  |
 | Changing the "Time per Scan Line" (and "Time per image") settings in Image Properties is being persisted. These parameters are used for time domain noise and vibration analysis in Fourier. |  |
| Calibration Module |
 | The ISO5436 step height feature now also works for profiles not extracted from an image |  |
 | Fixed in-active "Fine Linearity" toolkey after "Close All Except Main" |  |
| Particle & Pore Analysis Module |
 | Fixed redrawing of Measure Shape labels when one window has been covering another |  |
| 3D Visualization Studio Module |
 | 3D windows are no longer corrupted in "Save Screen" and "Copy Screen" images |   |
| Batch Processing Module |
 | When saving all windows to file in a batch process Average Profile and Average Fourier Profile windows are now stored with unique file names |   |
 | Color clip markers are now reset after Plane Correction during Batch Processing |  |
| Force Curve Analysis Module |
 | Implemented support for NT-MDT point and shoot force curves. The force curves can be selected individually from their recording positions shown in the spatial image and be analyzed automatically |   |
 | Worm-like chain (WLC) detection does now accept single pull-off events |  |
|
| SPIP™ v. 5.1.2 (2010-05-07) |
| Basic Module |
 | Aarhus STM .MUL image file reader reads more meta information and calibrates Z-scale according to voltage gain. |   |
 | The undo list is now cleared when Undo is switched off (in Undo Settings) |  |
 | Now Pa (Pascal) and eV (electron volts) units (e.g. from in Nanoscope files) are interpreted and displayed correctly in profile views |  |
 | Fixed problem reading non-square images from MDT NanoEducator files |   |
 | All traces are now loaded from Innova spm Force Curves files containing multiple force curves. |   |
 | Introduced double check that SPIP is started with Administrator rights |  |
 | Improved user friendliness of the Evaluation Dialog |  |
 | Improved messages in the License Manager and the Evaluation Dialog |  |
 | Removed "Don´t Show again" check boxes from language change dialogs |  |
 | Corrected Help text for the More Pixels function |  |
 | Improved performance of maximized view of 2D image windows |  |
 | Corrected occationally missing redraw of 2D windows when toggling the Color Bar on/off (occured in SPIP 5.1.0) |  |
 | Profile Subtract from All Lines in Main now sets Color Clip Markers to their default positions |  |
 | Corrected that under some circumstances AOI would not be taken into account by the "Set Bearing Height to Zero" Z-Offset Method in Plane Correction. |  |
 | Plane Correction: "Handle Steps" algorithm has been improved, especially the interplay with the "Max Flatness Tilt" feature |  |
 | Fixed rarely occuring crash when dragging files from Outlook to SPIP |  |
| Calibration Module |
 | Fixed wrong origin of error markers in the Main Image created by the Fine Linearity Correction feature. Error occured in SPIP 5.1.0. |  |
| Extended Fourier Analysis Module |
 | Improved stability and memory load of the FFT and Calibration modules |  |
 | Left Color Bar Markers (contrast markers) are now decoupled from the FFT theshold filter sliders. |  |
| Batch Processing Module |
 | New "Reload" batch processing item implemented. This feature reloads the original source image for each loop. Thereby it has become much easier and reliable to apply multiple processes to the same original image |  |
|
| SPIP™ v. 5.1.1 (2010-03-26) |
| Basic Module |
 | Opening files from command line is no longer creating multiple instances of SPIP. Problem occured in version 5.1.0 |  |
|
| SPIP™ v. 5.1.0 (2010-03-23) |
| Basic Module |
 | SPIP has been expanded with a license management interface.
In the new License Management Dialog, it is possible with a single mouse click to switch between three types of licenses: Local Dongle License, Shared Dongle License, and Evaluation License.
All information about expiry date, maintenance perioed, active Modules, owner name etc, is displayed for the selected license type. For testing purposes it is possible to temporarily disable active SPIP modules in order to try the look and feel for a specific modules configuration. This is especially useful for new users trying SPIP with an evaluation license.
Connecting to a Shared Dongle is also carried out from the License Manager and has become extremely simple.
Finally it is possible to request and activate an Evaluation License from the License Manager. This is intended for users owning a license with expired Maintenance Period who would like to try the newest version or users owning a license with a sub-set of modulea who would like to try the remaining modules.
Users who have no license dongle configured on the PC will be met by the Evaluation Dialog. From there it is possible to activate SPIP for a 10 days trial, or request a new evaluation period. For users holding a valid license there is a link directly to the License Manager, where e.g. connection to a Shared Dongle can be established. |  |
 | A Shared Dongle License Server installation program is now provided, so that setting up a dongle share service is much easier than in the past. |  |
 | 2D image windows can now be maximized as the 3D image window and the curve windows have been able to for a while. Fast switching between maximized windows can be performed with + |  |
 | "Bad" scan lines can now be removed using Average Profiling, either from Plane Correction or from the "Cursor Function Toolbar" and Single Curve windows context menu, Cursor functions: "Correct data between cursors...." |  |
 | In the Single Line Profile window the color of the "Line No." readout and the color of the fitting equation now gets the same color as the axes legends (Text Color). Further, the readout area in the Single Line Profile window, Histogram Window etc. now gets the same background color as the Grid background (i.e. the plotting area), which can be adjusted in the ViewSettings. |  |
 | Void pixels are now recognized in Wyko/Veeco .opd files |   |
 | Void pixels are now supported for saving and opening ascii (.asc) files |   |
 | Improved void pixel accuracy when rotating images with void pixels |  |
 | All Void Pixel commands now works inside AOI only, both for estimation and setting pixels values |  |
 | Fixed Plane Correction "Apply when Loading" feature which for certain plane correction settings has not been functional for multi-image files since version 4.7.5 |  |
 | Occational failure to adjust the colorbar contrast markers to the default values specified in Image Properties when loading multi image files has been fixed |  |
 | Fixed issue that color clip markers were not reset correctly in the Heuristiuc Fileimporter |   |
 | Fixed wrong reset of Color bar Clip Markers when executing Plane Correction with "VOI only" enabled with an AOI present in the Main image. |  |
 | Fixed broken correspondance between the "Void Pixels - Show as Invisible" menu command and the Show/Hide Void Pixels option in the 2D image ViewSettings. |  |
 | All Void Pixel commands now works inside AOI only, both for estimation and for modifying pixels values |  |
| Particle & Pore Analysis Module |
 | Fixed number of decimals in Shape Measurements pane to the design value of 6. From SPIP 5.0.4 only 2 decimals have been shown. |  |
 | Shape parameters for images in pixels units have erroneously been scaled as if the units were metric but without displaying so. This has been fixed so that non-metric units are never scaled. |  |
 | Corrected bug in Shape Measurements Pane: When a column was dragged out, the column layout in the Statistics section would not adjust |  |
| Force Curve Analysis Module |
 | SPIP now supports the saving and opening scatter plots such as force-separation curves in the .bcr and .bcrf formats. |   |
| Movie & Time Series Analysis Module |
 | Fixed bugs in Movie Export resulting in wrong definition of export region, wrong number of frames per second, and unaesthetic autoscaling of units in the nanometer range. Further, lack of initialisation of Color Clip Markers (and overlay) has been fixed. All bugs occured in version 5.0. |   |
|
| SPIP™ v. 5.0.8 (2010-02-10) |
| Basic Module |
 | The NanoSurf .nid reader is now extracting the axis labels so that they are shown in the curve windows |   |
 | The Heuristic File Importer does now handle the Z-scale factor for files containing float data. |   |
| Force Curve Analysis Module |
 | Implemented Seiko Force Volume (.xqh) file format |   |
 | Corrected reading of JPK .out force curves |   |
 | Image Calculator is now resetting the Color Clip Markers on new calculations |  |
|
| SPIP™ v. 5.0.7 (2009-12-21) |
| Basic Module |
 | Implemented NanoEducatorSPM topographic format of NT-MDT |   |
 | Enabled "Duplicate" in context menu of curves |  |
 | Handling µm unit for wsxm format |   |
| Calibration Module |
 | Corrected problem where "Align to Main" causes clipmarkers to move outside z-range |  |
 | Now showing ISO 5436 grid coloumn headers in correct language (e.g. Japanese)for profile analysis |  |
| Roughness & Hardness Analysis Module |
 | Calculation of the fractal dimension D corrected to be (6+s)/2 where is ´s´ is the (negative) slope of the average log-log Fourier amplitude spectrum for all directions |  |
| Batch Processing Module |
 | Corrected possible crash in Active Reporter when MS Word is having other plug-ins attached, such as Adobe Acrobat |  |
 | Corrected situation where only XY Calibration from first image is put into Active Reporter during a batch process |  |
| Tip Characterization Module |
 | Corrected possible crash when performing tip characterization on profiles |  |
|
| SPIP™ v. 5.0.6 (2009-11-27) |
| Basic Module |
 | Profile View Settings is now updated when "Show Cursors in Image" is changed from context menu |  |
 | Corrected disapearing "decade buttons" attached to spin buttons |  |
 | Preventing crash when trying to save force vs separation curves and other scatter diagrams in BCR format |  |
 | Corrected wrong color scaling when performing plane correction on image when using AOI and where the number of window pixels is smaller than the number of image pixels. This could also cause wrong behaviour of histogram cursors. Problem introduced in version 5.0.2 |  |
| Calibration Module |
 | Corrected problem with display of ISO 5436 Grid coloumns when togling between "Entire Image" and "Profile" |  |
 | Preventing potential crash when trying to perform Z-calibration on non main image or profile |  |
| Extended Fourier Analysis Module |
 | The Scaling method shown in the dialog is now consistent with the one applied. Inconsistency could occur on first use of the dialog within a SPIP session. |  |
 | Corrected calculation of fractal dimension. Calculation was mistakenly based on Fourier power spectrum instead of magnitude spectrum. |  |
 | Corrected x-axis for Fourier image profile graph |  |
 | Corrected log-log version of Fourier Image profile to show y values in log scale instead of linear scale |  |
| Particle & Pore Analysis Module |
 | In "Advanced Threshold" mode "Particle Range %" and "Pore Range %" are now defined relatively to the height range above and below the "Detection Reference Level" respectively |  |
 | Corrected potential change of "Pore RMS Factor" when modifying "Particle RMS Factor" |  |
 | In Threshold mode corrected potential movement of color clip marker when moving the other marker after having changed the "Threshold Level" from "Automatic" to "Fixed Level" |  |
 | Now remembering coloumn order of "Shape Measurements" results pane between sessions |  |
 | In active reporter corrected missing statistical shape parameters: mean, median, fractile, mode, area weighted mean and volume weighted mean values in situations where only one shape was detected. |  |
| Force Curve Analysis Module |
 | Updated Asylum Force curve reader. Now reading x, y values and resampling into equidistant z positions. Also extracting Spring constant |  |
 | Corrected potential crash in Multi Curve window when calculating "Mean Curve" or "Standard Deviation" of Force Curves extracted from Force Volume images. |  |
 | Auto apply is now working when changing Cantilever Sensitivity or Spring Constant |  |
|
| SPIP™ v. 5.0.5 (2009-10-08) |
| Basic Module |
 | Adjusted cursor positioning and mouse catch area for histograms. This solves problem where the cursors could be difficult to catch for histograms with very few bins |  |
 | Now ressetting Color Clip Markers when running "Define Zero by Active Cursor" in associated curve window. |  |
| Extended Fourier Analysis Module |
 | Prevented crash when correcting image from unit cell result dialog |  |
| Roughness & Hardness Analysis Module |
 | Fixed issue where plug-in roughness parameters did not appear in the roughness parameter selection list (since version 5.0.0) |  |
| Particle & Pore Analysis Module |
 | Corrected situation where the relation to the detection image is lost when loading a new settings file |  |
 | The object-marker for Shapes displayed as a fiber or a skeleton is now shown on the skeleton and not on the Shape periphery |  |
| Batch Processing Module |
 | Enabled height calibration for profiles by use of Batch Processing |  |
 | Enabled roughness analysis of profiles in a batch process |  |
| Filter Module |
 | Filter button changed to be a push button rather than a state button |  |
 | The output of iterative ISO11592 iterative filters is now showing the waviness image while the roughness image is shown as the difference image. This way the filter work as a smoothing filter similar to the other Gaussian filters. |  |
 | Corrected behaviour when pressing the Enter key when editing an input field in the ISO 11562 filter dialog so it will not apply the filter nor change the entered value. |  |
 | Corrected situation where the AOI region is being reset by the Erotion of Dilation functions |  |
| Tip Characterization Module |
 | Extended deconvolution image file name with "_deconvoluted" for easy recognition |  |
| Force Curve Analysis Module |
 | Implemented JEOL .spc Force Curve file format |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Added support for single-line CITS "images" and preventing crash for such images |  |
 | Corrected situation where rubber band selection of STS curves in the image does not update the STS curve window for curves which have previously been unmarked |  |
|
| SPIP™ v. 5.0.4 (2009-09-17) |
| Basic Module |
 | Corrected unit label for logDMTModulus images in Nanoscope 8 images |   |
 | Unnecessary warnings when reading certain Nanoscope 4.23 force volume files removed |   |
 | Corrected background drawing of Color Bar Editor |  |
 | We apologize to our customers, but the copy-paste function for 2D windows was "broken" in SPIP 5.0.2. This has now been fixed. |  |
| Batch Processing Module |
 | It is now possible to run Batch scripts from plug-in without display of the Batch Processer dialog and the Active Reporter progress bar. This makes running batch scripts from plug-in silent and smooth. |  |
 | Missing details for Z Calibration Active Report items added to the Active Report Control editor (SPIPDocserver) |  |
| Force Curve Analysis Module |
 | Corrected X-Scale of ASCII formated .mi force curves files |   |
|
| SPIP™ v. 5.0.3 (2009-09-09) |
| Basic Module |
 | SPIP can now read NanoNis .sxm files with large headers |   |
 | Exchange with Main feasture (shift+crtl+E) with legacy behavior (re-)introduced in SPIP 5.0.2 now also works in Japanse and Chinese language modes. |  |
 | One position shift of tool keys in certain toolbars have been fixed (occurred in SPIP 5.0.2) |  |
| Particle & Pore Analysis Module |
 | Fixed wrong position of Color Clip Markers when loading a new Detection Image having Automatically "Duplicate Main ..." and "Close all Windows.." disabled |  |
 | Fixed non-functioning smoothing filter in Watershed-Packed Features detection method (occurred in SPIP 5.0.2) |  |
|
| SPIP™ v. 5.0.2 (2009-09-03) |
| Basic Module |
 | Units for Shape labels are now controlled via Shape Measurements (Parameters) set-up. |  |
 | A warning is now displayed when trying to open an intermediate Nanoscope binary file, which can not be interpreted completely. The Heuristic File Importer will not open automatically. |   |
 | The Color Bar Editor is no longer displayed automatically when changing between build-in color scales. |  |
 | Exchange with Main Image function can now preserve profiles and other decorations of the windows by clicking Ctrl+Shift+E |  |
 | For un-recognized files a prompt is now shown instead of starting the Heuristic File Importer automatically |   |
 | Fixed problem introduced in SPIP 5.0.0 that could prevent SPIP from running on Client installations. |  |
 | Single line profiles and zoom boxes can no longer be activated outside the actual image display area inside a 2D window. |  |
 | Units in Nanoscope scanning capacitance files are now interpreted correctly |   |
 | Corrected adoption of color scaling from other image window when modifying the color bar markers without having the color scale editor open |  |
 | Corrected x-axis for for 1D Fourier zooms |  |
 | Fixed problem where SPIP could not read files locked by other applications (problem introduced in SPIP 5.0.0) |   |
 | Fixed potential crash when changing ViewSettings for profile curves. |  |
 | Activation of Measure Grid enabled for customers not having the Particle and Pore module |  |
 | Solved potential crash at start-up in a situation where the settings (SPIP.ini) from an older SPIP installation is imported on installation, and measure parameters that are no longer applicable are specified for the result pane |  |
 | Fixed problem where overlay color was always used for the maximum image value |  |
 | Missing Abs menu item in the Scaling sub menu of the Processing menu reintroduced. |  |
 | Fixed missing update of measurements when resizing the Line measure tool |  |
 | Void pixels can no longer be shown with overlay colors |  |
 | Missing "Duplicate" items in context menus reintroduced |  |
 | Fixed potential crash when moving lower color contrast marker outside upper color bar range |  |
| Extended Fourier Analysis Module |
 | Default FFT Color Clip Overlay colors changed to black and white with zero tranparancy |  |
 | Color Clip Markers of the Fourier image window will now keep their position when a new scaling mode is selected. |  |
 | Fixed mirroring of inverse FFT image occuring when number image points in Y is less than number of points in X |  |
| Particle & Pore Analysis Module |
 | Labels (ID or a calculated parameter) can now automatically be shown for each shape inside the Measure Image. Features display of number+unit or identifier+number+unit. |  |
 | The Gaussian convolution filter for the Watershed detection methods has been improved, especially with respect to border handling. |  |
 | Included Particle & Pore Area and Volume weighted histograms for Active Reporting |  |
 | Fixed situations where labels are shown with only units and no number |  |
| Batch Processing Module |
 | In the Batch Processing dialog the ActiveReporter output file and folder is now displayed and stored without the path, when the path is the default path. The output settings are now stored in the .batch settings file. This improves the user experience, and makes it easier to transfer batch files between different SPIP versions. |  |
| Filter Module |
 | Added enough space to Filter Dialog so that all controls are visible for all languages |   |
 | Fixed crash when filtering profiles (ocurred in 5.0.1) |  |
 | Fixed potential crash in Outlier Filtering |  |
| Imagemet Explorer Module |
 | The IMExplorer database has been compressed, so it can contain many more images before reaching its limit. |   |
 | Thumbnail browsing is now possible even after the database has reached its limit (2 Gb). |   |
 | Implemented Standard Windows behaviour when drag-dropping files in ImageMet Explorer. Meaning that the destination folder is not opened. |   |
 | Preventing crash when database file is not accessible. Can now continue with out use of the database file |   |
| Force Curve Analysis Module |
 | RHK sm3 force curve format implemented |   |
 | Implemented Veeco Innova .dat force curve files |   |
 | Fixed crash in force volume when using "Align Snap-in Heights" or "Equal snap-in deflection" |  |
 | Force Curve dialog is no longer closed on when pressing the Enter key |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Fixed creation of unexpected multi-curve windows when duplicating a spatial images with connected SPS curves. |  |
| Plug-In Interface Module |
 | Force curves and force volume images are now supported via plug-in; both processing and file reading. See example code generated by the Project Creator. |  |
 | Scatter plot is now supported via plug-in. See example code generated by the Project Creator |  |
 | Omitting warnings when listing available plug-in functions when non-applicable dlls are found in UserDLL folder |  |
 | Corrected potential crash when closing plug-in generated data window with void pixels before closing the Void Pixel info dialog |  |
 | Plug-in functions again be activated from Batch Processing, - problem introduced in version 5.0 |  |
 | Fixed problem where the project generator did not generate files with the expected names for "Visual Studio 2008 C++ No Dialogs" and C# projects |  |
|
| SPIP™ v. 5.0.1 (2009-07-09) |
| Basic Module |
 | Implemented reading of Agilent PicoView force curve ASCII and Binary formats |   |
 | Implemented reading of .sdf files from Zeiss Confocal Scanning Microscopes |   |
 | Implemented reading of the Z Sensor channel in Nanoscope 8 files from the Veeco Dimension Icon SPM |   |
 | Expanded Molecular Imaging file reader to handle large headers |   |
 | Measure objects (Shapes, multi profiles) and AOI´s are now automatically selected after drawing for easy manipulation. Further, in order to make it easier to move small objects the default mouse action on objects not selected is now Move (and not as before Resize) |  |
 | Z offset correction in Plane Correction Dialog is now as expected controlled by "Correct VOI Only" when clicking on the Z Offset Apply button |  |
 | Fixed occasional error in handling of the unit Newton |  |
 | Fixed Ampere scalability issue occured in SPIP 5.0.0. Affects the reading of current channels |  |
| Calibration Module |
 | In SPIP 5.0.0. the statistics section in the ISO5436 spreadsheet results dialog had become corrupted. This has now been reverted. |  |
| Roughness & Hardness Analysis Module |
 | Fixed occasional hiding of first line in resuts dialog, occured in SPIP 5.0.0 |  |
 | Unfortunately the number of significant digits for roughness parameters had been reduced in SPIP 5.0.0. This has now been reverted. |  |
| Particle & Pore Analysis Module |
 | Improved performance and usability:
- Faster Nearest Neighbor calculation
- Faster Fiber Lengh calculation
- Faster update when changing Shape transparency on the Output tab |  |
 | Holes in Shapes are now preserved when images are duplicated |  |
 | Fixed rounding error in the calculation of default Max limit in Parameter Filtering |  |
 | Fixed erroneous calculation of area and length based parameters of Shapes containing holes when Parameter Filtering was applied |  |
 | Fixed column header confusion when Copy Section (and paste) in the Shape Measurement pane was executed imidiately after multiple interchange of columns. |  |
 | Fixed error when saving Shape Measurement results to .grn file while focus was in another window |  |
| Force Curve Analysis Module |
 | Unfortunately the number of significant digits for force curve analysis parameters had been reduced in SPIP 5.0.0. This also affected the number formatting in the Shape Measurements pane after a force curve analysis. This has now been reverted |  |
|
| SPIP™ v. 5.0.0 (2009-06-24) |
| Basic Module |
 | No more showing color bar editor automatically when moving color bar markers in image window. |  |
 | Histogram markers are now keeping their absolute height position (on x-axis) when changing the number of bins. |  |
 | Keyence parameter files are now only generated for temporary use and deleted after reading. |   |
 | Rubberband selection of MeasureShapes, Multi Line Profiles, STS/CITS and Force Volume curves inside an image is now possible. |  |
 | Image files with extension .map and formated as SPIP ASCII format can now be read (like the .asc files). |   |
 | Color clipping limits now shown in the image as semitransparent overlays. The colors and transparency is fully customizable in View Settings. |  |
 | Y-axis units for histograms can now be configured in View Settings to display either in Percent, Fraction or Count. |  |
 | Corrected automated processing of self generated files in batch processing when putting files into active Sniffer folder. |  |
 | Corrected wrong x-unit in histograms which could occur for images opened in ASCII format. |  |
 | When reading curve data saved in the SPIP ASCII format the x-offset value is now read correctly. |  |
 | Histogram graph markers stepping now aligned to the bins. |  |
 | The XY offset can now be modified correctly when the offset mode is set to "Lower Left Corner" in Image Property dialog. |  |
 | Fixed problem with occasional unpredictable Z-offset when changing the Z unit in the Image Properties dialog |  |
| Roughness & Hardness Analysis Module |
 | Area measurement by Abott Curve adjusted to give same results as Histogram and use the AOI properly. |  |
| Particle & Pore Analysis Module |
 | NEW Particle & Pore Analysis Module
Detecting and quantifying particles, pores and grains have never been easier thanks to the brand new user interface to Particle & Pore Analysis and the new Best Practice Guide in the SPIP™ manual. You can detect any type of surface feature on virtually any background with just a few mouse clicks.
Four image feature detection methods are available based on two different segmentation principles: threshold segmentation and watershed segmentation.
Detected image features are shown in the image as manually drawn Measure Shapes and can be deleted, duplicated, moved, split and merged. Hence, the manual measure tools and the Particle & Pore Analysis tool are 100% integrated.
The detected features are shown directly in the source image, as semi-transparent objects, which can be colored randomly, with a fixed color or by a calculated parameter which is used for color lookup.
More than 60 geometrical parameters are calculated and reported in a spreadsheet like pane including advanced statistics and summary information.
All calculated parameters can be visualized by Histograms and scatter plots. This includes area- as well as volume weighted histograms which are powerful for presenting image data from e.g. ultra-filtration membranes where many small pores often dominate the numbers, but where the functionality is governed by the larger Pores.
For elongated structures, e.g. DNA, SPIP™ now provides visualization of the fiber, and calculates the fiber length.
Shapes can be discriminated on all more than 60 calculated parameters using Parameter Filtering.
The contours of the detected features can be smoothed; a great advantage on noisy images or whenever features appear irregular in the image even if they are not.
It is now possible to use one image for detection while using the height information from a second image which is useful e.g. when features are well defined in an phase-image of an AFM dataset, but the quantifiable information lies in the topography image.
Favorite settings can be saved and re-used either manually or in Batch Processing and Active Reporting. |  |
| Batch Processing Module |
 | SPIP Active Reporter improved.
New “SPIP DocServer” makes it easier to create MS Word and HTML templates where report items such as calculated parameters, graphs and images can be entered.
SPIP DocServer enables you to select among a larger number of report items. It is for example possible to combine two Particle & Pore Analysis parameters into a scatter plot.
The SPIP DocServer fully supports MS Word2007 and enables creation of HTML templates using any text or HTML editor via copy-paste.
The speed of Active Report generation based on MS Word templates has been more than doubled. |  |
| Filter Module |
 | AOI is now supported for Erotion and Dilation operations. |  |
 | Added enough space to Filter Dialog so that all controls are visible on Japanes Window systems. |  |
 | Now handling AOI correctly when performing filtering where the result is set to be put into the source window, such that non-AOI areas are preserved. |  |
 | Corrected missing undo functionality when Filter Difference was sent to Source Window. |  |
| Imagemet Explorer Module |
 | Occational crash on certain tiff files fixed. |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Rubber band selection of multiple IV curves in STS and CITS images. It is now possible to select all curves recorded in one point. |  |
|
| SPIP™ v. 4.8.7 (2009-05-07) |
| Basic Module |
 | Removed installation dependency to previous SPIP version |  |
|
| SPIP™ v. 4.8.6 (2009-05-05) |
| Basic Module |
 | Japanese and Chinese translations for new "Subtract from all lines in Main Image" feature |  |
 | Implemented Keyence file format |   |
 | Progress bar shown when reading large JPK and PSIA files |   |
 | Reduced time for interpreting large .txt files |   |
 | Implemented JPK force volume format (ascii .map_txt format) |   |
 | Histograms in ".asc" format are now exported without offset |  |
 | Height Histogram: Solved incorrect application of AOIs on the calculation of Area Void- and Material Volume. Changed relative weight of pixels by (1/Nx x 1/Ny) for calculation of Area Void- and Material Volume. This has no significance for the average user. Only users using histograms to the maximum precision will be affected (ask for support note). |  |
 | Fixed un-intended application of AOIs when using interactive tilt in Plane Correction. |  |
 | Improved positioning of x-axis labels (images and curves) |  |
| Extended Fourier Analysis Module |
 | Prevented Inverse Fourier image to display when the Fourier module is called from other functions in SPIP |  |
| Roughness & Hardness Analysis Module |
 | Solved issue that AOIs created by duplication were not taken into account in roughness analysis |  |
| 3D Visualization Studio Module |
 | 3D: Fixed wrong line width for axis corners and grid frame |  |
| Batch Processing Module |
 | Japanese and Chinese translations for new Zoom Box Setup and Line Profile Setup batch functions |  |
 | Fixed occational crash when closing the force curve analysis parameter selection dialog after a batch process |  |
|
| SPIP™ v. 4.8.4 (2009-03-23) |
| Basic Module |
 | Implemented WSxM short integer format |   |
 | Added support for RHK .SM4 file format. Feedback is highly appreciated. |   |
 | Square zoombox can now be forced by holding down the shift key while dragging. |  |
 | New "Subtract from all lines in Mail Image" feature. Its is now possible to subtract a profile from all lines in the Main Image |  |
 | New driver from license key solution provider. Reduces the risk of corruption of a shared license file. |  |
 | New driver for old license keys supports 64 bit Windows Vista |  |
 | Solved occasional crash when ellipse or polygon measure tools were moved outside the image area |  |
| Calibration Module |
 | Corrected angular distortion calculation in xy calibration when Cx or Cy >>1 |  |
 | Fixed crash when entering unit cell values in the XY correction dialog manually. Avoid display of fourier transform when applying correction. |  |
 | Fixed issue when swapping of Peak 1 and Peak 2 in the Fourier Image would result in different correction factors after unit cell calculation. |  |
| Extended Fourier Analysis Module |
 | Fixed issue when the unit cell vector coordinates in the Fourier dialog were not updated after interactive calculation of alternative unit cells. |  |
| Batch Processing Module |
 | New batch processing function for setting up the profile position and placement of cursors for cross section profiles. Includes averaging function and option to see dimension readout directly on the profile. |  |
 | New batch function allows setup of size and position of the zoom box |  |
 | Corrected the updating of roughness parameters in the Main window when a SPIP batch script is executed from command line |  |
| Imagemet Explorer Module |
 | Fixed poor contrast in thumbnails of some Nanosurf .ezd files |   |
| Force Curve Analysis Module |
 | Non-measured points in the approach curve of Nanoscope force-volume fiels are now substituted by the first valid point in the curve. |  |
 | The y-offset in force-speration curves is now always enherited from the baseline corrected data. |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | The position of a selected spectroscopy curve (STS) in the multi curve view is now indicated by a cross-hair marker in the corresponding STM image |  |
 | Disabling CITS tool keys when not applicable (non CITS images) |  |
|
| SPIP™ v. 4.8.3 (2009-02-25) |
| Basic Module |
 | Potential crash in line measure tool fixed (appeared in 4.8.2) |  |
 | Fixed occasional display of wrong z scale after plane correction with AOI (appeared in 4.8.1) |  |
 | Fixed occasional disabling of View Settings pane after Close All Windows |  |
| Calibration Module |
 | Fixed interchanged Upper/Lower Width statistics columns in ISO5436 result pane. |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | CITS context menu re-enabled (missing in version 4.8.1 and 4.8.2) |  |
|
| SPIP™ v. 4.8.2 (2009-01-21) |
| Basic Module |
 | Implemented .DAT fileformat (2D and 3D) from AEP Technologies |   |
 | Implemented Zemetric, .zmp, file format |   |
 | "The Main Window been closed...." messages are not shown anymore when windows are closed automatically. |  |
 | Colorbar contrast markers are now reset to default values after plane correction. |  |
 | Disabled automated z-offset correction when applying "Correct selected cross section" from Plane Correction dialog |  |
 | Void pixels menus: Japanese and Chinese translations now correspond 100% to the English version. |  |
 | Potential crash in multiprofile window appearing in version 4.8.1 (only) has been resolved. |  |
| Calibration Module |
 | ISO5436 height calibration: Number of significant digits has been increased. Full precision now used in the statistics section. |  |
 | Critical dimensions (ISO5436) now also works with automatic fitted curve subtraction. |  |
| Extended Fourier Analysis Module |
 | Potential flicker and displacement in the Fourier filter image for higher order Butterworth bandpass filters has been fixed |  |
| Roughness & Hardness Analysis Module |
 | Only show high sq roughness warning when running roughness process. |  |
 | Roughness chart of a single parameter now displays correctly |  |
| 3D Visualization Studio Module |
 | If 3D Surface Mode is set to "Other Image", Palette Limits now use the other image´s Z unit. |  |
| Batch Processing Module |
 | When upgrading SPIP, settings files including Active Report templates modified or created by the user can now automatically be transferred directly to the corresponding folders in the new version. This makes upgrading much smoother and deep folder trees are avoided. |  |
 | Problems with first time execution of Filter Specific in batch has been resolved. |  |
| Imagemet Explorer Module |
 | Thumbnails in ImageMet Explorer for .MUL files are now shown correctly (non-inverted) |  |
| Plug-In Interface Module |
 | Plug-in file-importer can now also handle void pixels |  |
 | Small memory leak in fileimporter plug-in fixed |  |
|
| SPIP™ v. 4.8.1 (2008-12-15) |
| Basic Module |
 | Omicron SCALA files reader now also handles Unix linefeeds. |   |
 | "Set Outside Markes to Void" now also available in Processing/Void pixels and in image right-click menu |  |
 | Nanosurf: Implemented reading of amplitude and phase spectroscopy curves |   |
 | Reading more variants of Anfatec files |   |
| Roughness & Hardness Analysis Module |
 | In the roughness parameters selection list Sv/Rv and Sp/Rp have been renamed from "Minimum Height" and "Maximum Height" to "Max Valley Depth" and "Max Peak Height", respectively, which is consistent with the ASME46.1-2002 and ISO4287:1997 standards |  |
| Batch Processing Module |
 | Batch Processing Button converted to Toggle Button to ease understanding of the state |  |
| Force Curve Analysis Module |
 | Preventing potential crash when reading Asylum force curve files with missing y-axis information. |   |
|
| SPIP™ v. 4.8.0 (2008-11-20) |
| Basic Module |
 | Added support for 32 bit Agilent file format |   |
 | Added support for Alicona MeX Stereo SEM .al3d file format |   |
 | Now printing line number in print footer for profiles |  |
 | Color Clip Markers reset to neutral position after plane correction, to get best color scale |  |
 | Added xlabel, ylabel and zlabel for description of the dimension axes in the BCR file format |   |
 | Enhanced conversion of lenght units in Omicron Matrix force curve files. |   |
 | Plane Correction by Sphere fit improved and use of AOI implemented |  |
 | Legacy limit for up to 10 force curves in files from Molecular Imaging AFMs removed. |   |
 | Traditional and simplified Chinese language versions implemented |  |
 | Fixed drawing error when moving the angle measurement tool |  |
 | Aspect ratio in newer Veeco Nanoscope files is now correct |   |
 | Unit and type now read correctly for non topographic Asylum Research images |   |
 | Multi Line Profiles are now carried over when a new image is loaded into the main window |  |
 | Disabled Radius of Curvature and Cone Angle fit for profiles having non-length units on the x- or y-axis |  |
 | Main window can now be minimized |  |
 | Fixed problem where license server would slow down and eventually crash, seemingly due to accumulation of an extremely large number of users. |  |
| Extended Fourier Analysis Module |
 | Preventing potential crash when checking "Filter Ratio" on in the Fourier Output tab |  |
 | The Scaling method shown in the dialog is now consistent with the one applied. Inconsistence could occur on first use of the dialog within a SPIP session. |  |
| Roughness & Hardness Analysis Module |
 | Roughness parameters calculated by user plug-ins can be integrated in SPIP and displayed alongside the standard parameters in SPIP |  |
 | Removed limitations on Min and Max values in the Roughness Chart dialog |  |
| 3D Visualization Studio Module |
 | Using the ´3´ key to display images in 3D no longer causes display of the 3rd light source visualization. |  |
| Batch Processing Module |
 | User Plug-ins now availble in batch processing |  |
| Imagemet Explorer Module |
 | Copy by Ctrl+C now works in the description field in the ImageMet Explorer |  |
 | File info pane now always shows information for the selected file. If no file is selected, then no data is shown. |  |
| Tip Characterization Module |
 | The fitted radius curves are now placed correctly |  |
 | Updating all tip radius and cone angle results when changing detection count |  |
| Plug-In Interface Module |
 | Inserted browse link in SPIP to Plug-in download web page |  |
 | User Plug-ins now availble in batch processing. |  |
 | Roughness parameters calculated by user plug-ins can be integrated in SPIP and displayed alongside the standard parameters in SPIP |  |
 | Parameters calculated by user plug-ins can be interserted in Active Reports |  |
 | File importer plug-ins can now easily be integrated with SPIP and run seamlessly together with SPIP´s internal file readers. You can see your files in thumbnail view in the ImageMet Explorer and open them in SPIP |  |
 | Plug-in Project Creator extended with ready to build and run projects for C#, C++ File Import, C++ Roughness Parameter calculators, and C++ projects for the free Microsoft Visual Studio Express |  |
 | Corrected registration of Filename set from Plug-ins |  |
|
| SPIP™ v. 4.7.6 (2008-10-01) |
| Basic Module |
 | Corrected wrong scaling of the deflection channel and of the linearised height channel in certain Nanoscope images (occurred in version 4.7.5). |   |
| Calibration Module |
 | Graphical display of ISO5436 results for large curves corrected |  |
| Force Curve Analysis Module |
 | Activated auto apply function of Hysteresis Correction check box in Force Curve Analysis |   |
|
| SPIP™ v. 4.7.5 (2008-09-26) |
| Basic Module |
 | Showing Z-axis description along with Z-Range in image window when available. |  |
 | Implemented STS support for Oxford .top STM files |   |
 | Implementation of new Unisoku .usd file format with CITS support |   |
 | Now also supporting .asc files where line shifts are written as CR+LF (Windows like) as well as LF (Unix like) |   |
 | Now extracting spring constant from NanoScope Force Volume files |   |
 | Implemented reading of Ambios .txt single profile files |   |
 | Optimized number of digits and decimals for axes in 1D plots |  |
 | Corrected z-scaling of Adhesion, Dissipation, Peak Force and Stiffness of Veeco data files |   |
 | Corrected offsetting of x-axis values for filered curves |  |
 | Solved potential crash when calculating histogram for flat profile |  |
 | Z-unit for SPIP .asc file is now handled and can be different from the default "nm" unit |   |
 | Fixed error where "Reload" function would load the wrong image from Omicron Matrix files |   |
 | Fixed potential for wrong spectroscopy axis values for Omicron Matrix files |   |
| Roughness & Hardness Analysis Module |
 | Excluding Scl20 and Scl37 from calculation when max decay limit was outside image boundary |  |
 | Showing non-calculated roughness values as empty fields in grid report view |  |
| Batch Processing Module |
 | Fixed error when loading a large number of batch files |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Adjusted the calculation of the SPS curves image coordinates |  |
|
| SPIP™ v. 4.7.4 (2008-08-21) |
| Basic Module |
 | Reduced memory demand of Omicron Matrix file reader, so it is now possible to load any single external data file even for very large data sets. |   |
 | Corrected loss of synchronized profiling mode after closing windows |  |
 | Fixed skewed surface display when downsampling large images with odd number of pixels in X |  |
 | Solved situations where curve markers could not be removed from View Settings pane |  |
 | Corrected displaced fadius of curvature curve fit |  |
 | Corrected x-values of curves exported to ASCII files |   |
 | Corrected handling of long profiles, including:
Preventing potential crash when performing Fourier transform on very long profiles, by averaging Fourier results from smaller curve pieces.
Corrected Fourier x-unit from 1/nm to Hz for time domain curves
Faster handling of long profile data
Detailed zooming of large profiles made possible |  |
 | Fixed potential fatal error when SPIP Online pane is updated |  |
 | Removed notification when starting SPIP with no default printer selected |  |
| Roughness & Hardness Analysis Module |
 | Now showing Std and Stdi roughness parameters in Anglular plot |  |
| Force Curve Analysis Module |
 | Corrected situations where force curve cantilever sensitivity was multiplied with 1e9 when entered lower than 1e-3. |  |
 | Re-established correct interpretation of NanoScope force curves recorded while in force volume mode. |   |
 | Handling invalid data "tails" of Veeco NanoScope force curves by setting such data equal to the last valid data point |   |
|
| SPIP™ v. 4.7.3 (2008-08-07) |
| Basic Module |
 | Added support for Createc .dat files version 2.0 |   |
 | Solved incorrect title caption in Main Image Window after "Exchange with Main Image" |  |
 | Solved misaligned zoom image for images with x/y aspect ration lower than 0.06. |  |
| Roughness & Hardness Analysis Module |
 | Corrected display of too high hardness area measurement shown in detailed dialog. |  |
| Batch Processing Module |
 | New "Void Pixels" batch item to define certain height values as void. |  |
| Filter Module |
 | Gaussian ISO filter dialog: Remembering state of "Equal X,Y" and "unit" between sessions. |  |
|
| SPIP™ v. 4.7.2 (2008-06-11) |
| Basic Module |
 | Fixed error in Shimadzu file reading |   |
| Imagemet Explorer Module |
 | Solved problem with opening files by ImageMet Explorer tool key "Open file(s) in SPIP" after running batch process |   |
 | Corrected double display of newly saved files in ImageMet Explorer |   |
 | Corrected a potential crash when running a batch process from the ImageMet explorer with optional output to the database. |  |
 | Corrected potential crash when deletion a file from the ImageMet explorer followed by re-sorting |  |
|
| SPIP™ v. 4.7.1 (2008-06-05) |
| Batch Processing Module |
 | Corrected display of Force Curve result dialog at the end of a batch process even if no force results has been generated |   |
| Force Curve Analysis Module |
 | Added force volume support for NanoScope file format version 4.23 |   |
 | Corrected reading of PSIA Force Volume images |   |
|
| SPIP™ v. 4.7.0 (2008-06-04) |
| Basic Module |
 | Added functionality to close all data windows whenever a new file or set of files is loaded |  |
 | Updated PSIA reader to support new floating point format |   |
 | Implemented PNI file format v. 2.0 (with force curves) |   |
 | Added support for Lasertec .LMS format |   |
 | Added support for PSIA Force Volume files |   |
 | Corrected reading of Quesant file formats |   |
 | Solved potential access violation when closing SPIP with ImageMet Explorer open |  |
 | Solved potential crash when calculating histogram for flat profile |  |
 | Corrected small fluctuation in measurement tool values reported for length, breadth and orientation as function of the objects position |  |
| Calibration Module |
 | No longer showing NA instead of correction values when opening xy correction dialog with images larger than the reference pitch distances |  |
 | Print is now using the default margins also on first use. |   |
 | Corrected angular distortion calculation in xy calibration (only significant for large correction factors) |  |
 | Repaired possible display of ISO5436 results in wrong columns |  |
| Imagemet Explorer Module |
 | Corrected potential crash error when clicking View button in Info Pane during population of File pane |  |
| Force Curve Analysis Module |
 | Force Volume Support which enables you to select individual force curve pairs and mapping of new images showing calculated forces, heights and extracted parameters for all curves in the volume image.
The following image maps can be created:
- Detach Separation Image
- Snap-in Height Image
- Height Image interactively selected by markers in force curve window
- Max Adhesion Image
- Max Load Force Image
- Snap-in Force Image
- Youngs Modulus Sphere Image (from Hertz model fitting)
- Youngs Modulus Cone Image (from Sneddon model fitting)
The volume images may be corrected for artifacts using these dedicated function:
- Baseline Correct
- Hysteresis Correct
- Align Snap-in Heights
- Equal Snap-in Deflection
Furthermore, the individual force curves embedded in the volume image can be written to individual files and an average force curve pair can be calculated. |  |
 | Young´s modulus extraction by Hetz and Sneddon model fitting |  |
 | New Force Curve Dialog providing detailed control of detection and fitting parameters for baseline correction, pulling and indentation experiments. |  |
 | New Foce Curve Analysis parameters:
- Young´s Modulus
- Detach force
- Detach separation
- Zero indentation separation
- Loading rate at pull off event
- Unfold separation at pull off event |  |
 | Automated capture of numerical results for individual force curve pairs, which can be shown in a spreadsheet style grid window with statistics |  |
 | Implemented SIS .txt force curve file format |   |
 | Added support for Veeco Innova .psd file format (single spectroscopy and force curves) |   |
 | Added Force Curve read/write support for SPIP´s own ASCII format |   |
 | Added support for Veeco/NanoScope Force Volume files |   |
|
| SPIP™ v. 4.6.5 (2008-04-11) |
| Basic Module |
 | Corrected z-scaling of Toray images |   |
 | Updated file reader to read scan timing information from Omicron Matrix 2.0 files |  |
 | Corrected truncation error of area calculation by measure tools for small image dimension |  |
 | Solved resizing of zoom box in curve windows after moving the zoom box followed by mouse click else where on the screen |  |
 | Fixed potential crash when having a polygon measure tool selected and then changing the number of image pixels |  |
 | Solved rare problem where cursors in curve windows are not shown |  |
| 3D Visualization Studio Module |
 | Handling memory limitations in 3D for large images by down-sampling internally to appropriate size |  |
| Imagemet Explorer Module |
 | Sorting order for files and folders whose names contain numerals is now done with respect to the numerals. |  |
| Force Curve Analysis Module |
 | Implemented force curve support for PSIA .tiff files |   |
 | Handling of unmeasured data in Molecular Imaging force curves |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | When enabling display of calculated curves for images with more than one type of STS curves, The correct number of curve windows is now shown |  |
|
| SPIP™ v. 4.6.4 (2008-03-04) |
| Basic Module |
 | Implemented window snapping function. While moving or resizing data windows they will conveniently snap to neighbor windows when their borders get close. Can be neutralized by keeping the Shift key down. |  |
 | Synchronized profiling and Synchronized zooming is no longer creating windows in reverse order. Therefore, it is now easier to set up the related windows pairwise. |  |
 | Introduced workaround to error in Windows Explorer that prevents registration of file extensions with SPIP after upgrade of SPIP |  |
 | Support for KLA-Tencor P-16 format (.map and .3dd) |   |
 | Assuring removal of old zoom boxes when moving synchronized zoom boxes |  |
 | Fixed loading of single point spectroscopy curves from .SM3 files |   |
| Roughness & Hardness Analysis Module |
 | Ten point height changed according to standards. This will only influence results when some of the 5 deepest pits are positive or the 5 of the highest peaks are negative. |  |
 | Corrected optional 1. order plane correction when performing roughness analysis on profiles |  |
| 3D Visualization Studio Module |
 | Fixed potential crash when displaying popup menu for 3D window |  |
| Filter Module |
 | Increased max Gauss filter size from 4000 x 255 to 4001 x 4001 points |  |
 | Gaussian ISO filter dialog: Remembering state of "Equal X,Y" and "unit" between sessions. |  |
|
| SPIP™ v. 4.6.3 (2008-02-04) |
| Basic Module |
 | Extended bcr file format specification to allow variable header size |   |
 | PNI: Fixed wrong Z axis unit when unit is "mV" |   |
 | Corrected empty description fields for files in ImageMet Explorer database, which was inserted before version 4.6.2 |   |
|
| SPIP™ v. 4.6.2 (2008-01-29) |
| Basic Module |
 | Improved support for large images by enabeling SPIP to take advantage of extended virtual address space (4-Gigabyte Tuning) |  |
 | Implemented reading of Ambios .txt single profile files |   |
 | Description field in ImageMet Explorer expanded to fit descriptions extracted from file |  |
 | Corrected undesired cursor "trace" when having profile cursors in image on vertical cross-section lines |  |
 | Corrected z-scaling of NanoScope potential images |   |
 | Corrected change of unit when freezing axes of Voltage curves |  |
 | Corrected change of z-offset when changing z-scaling in Image Property dialog |  |
 | Omicron Matrix files: Triplets spanning more than one subrange are now interpreted correctly |   |
| Calibration Module |
 | Made ISO 5436 Step Height measurement available for single profile files |  |
 | Made slope measurements based on ISO 5436 Step Height measurements more robust against noise |  |
 | Fixed potential crash when closing the result grid after calculating critical dimensions by the ISO 5436 method |  |
| Extended Fourier Analysis Module |
 | Keeping excluded regions as excluded after inverse Fourier |  |
| Roughness & Hardness Analysis Module |
 | Corrected Area readout for interactive measurements on Abbott graphs |  |
| Particle & Pore Analysis Module |
 | Included units in Grain (.grn) result files and output |  |
| Batch Processing Module |
 | Implemented dy/dx function for curves in Batch Processor |  |
| Filter Module |
 | Preserving all filter output settings after closing Filter Dialog |  |
 | Corrected filter border mode behaviour for images of uneven pixel size |  |
| Force Curve Analysis Module |
 | Added Force Curve Support in BCR file format |   |
|
| SPIP™ v. 4.6.1 (2007-12-14) |
| Basic Module |
 | Menu "File, Save Screen..." now provides saving to BMP, JPEG and TIFF images. JPEG quality is set to 85%.
The "screen dump" is cropped to the minimal area containing all image and curve etc. windows. |  |
 | SPIPOnline Pane now uses default browser to open links |  |
 | Single profile and cross-hair profiles are now moving by one image pixel at a time when using the arrow keys, instead of one screen pixel. This enables visualization of profiles not shown in the image window when the number of window pixels are smaller than the source image. |  |
 | Axis labels for NanoScope HSDC stripchart files set as described in file |   |
 | Default view settings (Curves On/Off, Dimensions readout etc.) for Single Curve Windows are now applied when a new curve window is opened. |  |
 | Color bar can no longer obscure rightmost part of the image (could happen for very small window sizes) |  |
 | Unit settings for Y axis on curves are now saved and loaded correctly |  |
 | Line Measurement Tool Grid now shows parameter values in the correct columns |  |
| Calibration Module |
 | Corrected lateral shift of one pixel when performing linearity correction |  |
 | Corrected incorrect storing of correction linearity parameters after manual editing |  |
| Roughness & Hardness Analysis Module |
 | Corrected roughness analysis to take proper care of Area of Interest (AOI) when defined |  |
| Particle & Pore Analysis Module |
 | Using detection level as reference now works correctly |  |
| 3D Visualization Studio Module |
 | Fixed potential crash when using 3D autoupdate together with "2D AOI Color Scale" |  |
 | Fixed memory leak in 3D |  |
| Batch Processing Module |
 | HTML Templates can now be edited in MS Word |  |
 | Fixed insertion of extra linefeeds in reports by Word ActiveReporter |  |
 | Removed limitation where batch scripts could not be executed from the command line when SPIP was already running |  |
 | Corrected failed User Name insertion in Active Word Reports |  |
| Filter Module |
 | Solved potential crash when saving filter kernes which are larger in y than x |  |
| Imagemet Explorer Module |
 | Fixed incorrect expansion of multi files when expanded during population of folder |  |
 | Fixed crash on Windows Vista when using Reporter |  |
| Movie & Time Series Analysis Module |
 | Export of movies can contain a border. The size of the border is now minimized, and the color is set to the MDI client area color in stead of black. |  |
|
| SPIP™ v. 4.6.0 (2007-11-21) |
| Basic Module |
 | New tool for easy x,y-scaling of, e.g., SEM Images. The scaling tool can automatically find scaling bars in images and set the correct physical dimensions. |  |
 | The Polygon and Ellipse/Circle Measure Tools now calculate Material, Void, and Net Volume for all selections in stead of only Material Volume |  |
 | Implemented 8 channel images from Veeco |   |
 | Implemented reading of high speed capture files from Veeco |   |
 | Implemented reading of stitched maps from ADE/KLA Tencor |   |
 | Improved handling of panes with graphic guides for docking |  |
 | Automatic cropping of background to content for Copy Screen |  |
 | Customizable background color for client area |  |
 | Short cut Shift+Ctrl+D assigned to easy duplication of graphical objects (AOI and measurement tools) |  |
 | Updated DME MIF format support to version 1.10 |   |
 | Corrected reading of .sdf files |   |
 | Fixed missing hotkeys and view settings for new windows when not using Auto Tiling |  |
 | Added missing height calculations for the ellipse tool. |  |
 | Re-enabled setting favorite widow size in the "Set Window Size" dialogue for all image/curve windows. |  |
 | Help now works on Client installations |  |
| Roughness & Hardness Analysis Module |
 | 11 roughness parameters validated to be consistent with NIST by The Danish National Metrology Institute, DFM |  |
 | Optional preprocessing for direct comparison with roughness measurement generated with other software packages |  |
 | Isotropic Area Power Spectral Density graph for easy identification of dominant wavelengths and measurement of RMS roughness within frequency bands |  |
| Particle & Pore Analysis Module |
 | Solved diagonal discontinuity for Gauss filter results of images with uneven number x-, y-pixels. |  |
| 3D Visualization Studio Module |
 | Auto Update of 3D View when the source image is altered |  |
| Batch Processing Module |
 | Improved template design for Active Reporting with preface, values, and summary included in one template |  |
 | Solved potential crash when having 3D in batch process |  |
 | Avoiding pop up of Batch Dialog when Auto Run batch mode is active |  |
| Tip Characterization Module |
 | Now saving tip fitting parameters between SPIP sessions |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Fixed reading the correct section for the forward/backward spectroscopy images. |   |
|
| SPIP™ v. 4.5.8 (2007-10-26) |
| Basic Module |
 | Fixed installation issues |  |
| Force Curve Analysis Module |
 | For NanoSurf force curves the extending curve is exchanged with retracting curve when the extending curve is found to have the highest attraction force |   |
|
| SPIP™ v. 4.5.7 (2007-10-17) |
| Basic Module |
 | Implemented WSxM .stp file format |   |
| Filter Module |
 | Fixed error when showing Filter dialog (introduced in v. 4.5.6) |  |
|
| SPIP™ v. 4.5.6 (2007-10-11) |
| Basic Module |
 | Implemented new Veeco Innova .flt fite format |   |
 | Improved handling of license server settings on installation upgrades |  |
 | Improved handling of Client/Server installations and upgrades |  |
 | Improved handling of SPIPControl.ocx registration for multiple SPIP installations |  |
 | Corrected Heuristic File Importer for failing in reading data files in double precision floating points |   |
 | Fixed crash when when moving a non main image with AOI objects "To Main". |  |
 | Corrected pasting to Excel from Grid views |  |
 | Fixed potential crash when performing "Copy" of curve in multi curve window when y-unit was set to "Arbitrary" |  |
 | Corrected y-unit contact mode force curves from Volt to nm for older NanoScope file versions( version < 0x043 ) |   |
| Correlation Averaging Module |
 | Solved x,y mirroring problem when performing cross-correlation and correlation averaging on image with number of rows different from columns |  |
| 3D Visualization Studio Module |
 | 3D window context menu no longer has duplicated items after 3D window is closed and reopened |  |
 | Fixed memory accumulation error in Movie with 3D |  |
| Tip Characterization Module |
 | Tip characterization profiles are now again per default shown with 1:1 aspect ratio. Different behaviour was introduced in version 4.5.0 |  |
 | Fitted cone angles and radius of curvatures are now always shown for calculated tip profiles |  |
| Force Curve Analysis Module |
 | Fixed X-mirroring of NanoSurf force curve files when the height values at the contact region has the highest values |  |
| Movie & Time Series Analysis Module |
 | Removed black border on exported "Main window screen dump" movies |  |
|
| SPIP™ v. 4.5.5 (2007-09-19) |
| Basic Module |
 | Implemented reading of SPIP exported ASCII profiles and force curves |   |
| 3D Visualization Studio Module |
 | Fixed missing font names in default View Settings. This caused missing support for non-roman characters in 3D. |  |
|
| SPIP™ v. 4.5.4 (2007-09-14) |
| Basic Module |
 | When duplicating graphical objects the new object is now selected automatically |  |
 | Exported ASCII files now include the Description text from the image/curve |   |
 | Optimization of speed when using a large number of measurement/AOI/STS tools: View Settings are now only shown for selected items |  |
 | Increased robustness of dongle checking on busy USB |  |
 | Fixed portential crash when using Synchronize Profile in Multicurve Windows |  |
 | Fixed potential crash when canceling out of "Set Window Size" dialog |  |
 | Fixed crash occuring when either all ROI or measure tools are deleted while a polygon or ROI polygon object is being created but not completed/closed |  |
 | Fixed error that prevented setting offset on X- and Y-axis for 2D and 3D images in the Properties dialog |  |
 | Fixed y-mirrored STS positions in Omicron Matrix files |   |
 | Fixed wrong X-axis offset on STS curves (only when linked with image) |   |
| Particle & Pore Analysis Module |
 | Void areas are now marked as single segments, and automatically excluded |  |
| 3D Visualization Studio Module |
 | Non-roman characters are now shown with correct font size |  |
 | Fixed drawing of axes with extremely large offset |  |
| Batch Processing Module |
 | The "Window save all" command in batch processing is now appending the original file name with "_3D" for the images shown in the 3D window |  |
 | Batch Processing can now process individual selected images from multi-image files |  |
 | Added Erosion and Dilation functions to Batch Processing |  |
| Imagemet Explorer Module |
 | Fixed potential crash in Finder |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Added spectroscopy curve transformation functions for STS (Conductivity, Density of States, etc) |  |
|
| SPIP™ v. 4.5.3 (2007-08-16) |
| Basic Module |
 | Mask Main function updated: The two right-hand (color-clipping) markers determine upper and lower threshold. For all positions in the image with a value outside this interval, the corresponding position in the main image is set to void. |  |
 | The user can now reset the color settings (brightness and contrast) of an image to that of SPIP default by using "Reset Colors" |  |
 | Selecting and deselecting individual AOI shapes no longer affects the generated AOI mask |  |
 | Fixed error in data when saving to .bcrf format with void pixels (introduced in 4.5.0) |   |
 | Fixed scaling error in Wyko .opd files |   |
 | Colorbar is now exchanged correctly when exchanging an image with main, duplicating an image and setting an image as main |  |
 | Fixed occasional failure to read subimages specified on the command line (Omicron Matrix files only) |   |
| 3D Visualization Studio Module |
 | Fonts are now corectly mapped for asian characters on Japanese Windows XP and Vista |  |
|
| SPIP™ v. 4.5.2 (2007-07-31) |
| Basic Module |
 | Added support for reading Single point spectroscopy curves from the Scala Pro file format. |   |
 | AOI tools can now also work in auto exclude mode |  |
 | Fixed file sharing issue when reading Omicron Matrix files while conducting scanning (introduced in v. 4.5.0) |   |
 | Fixed crash when using menu "To Main" on a zoom window originating from the Main Image Window |  |
 | Corrected scaling of df channel data read from Omicron Matrix files |   |
| Imagemet Explorer Module |
 | Fixed error when trying to type in search criteria in Finder |  |
|
| SPIP™ v. 4.5.1 (2007-06-26) |
| Basic Module |
 | Modified functionality in "Set Values Outside Markers to Void" to just convert values outside the selected range to voids. |  |
 | Added a new method "Set Values Outside Markers and Spikes to Void" that converts values outside the selected range to voids including spiky neighbour pixels. |  |
 | Installer now allows selection of what version to copy settings from |  |
 | Fixed error message when closing SPIP (Japanese version only) |  |
 | Now saving ruler stick position (sticking to X/Y axis). |  |
 | Fixed bug where ruler displays units but has 0 length. |  |
 | STS curve window can now be recreated after close, by enabling marker(s) in the image window. |  |
 | STS curve markers can no longer be moved in the image window |  |
 | CITS markers and multi-profiles can no longer be dragges outside the image. |  |
| Roughness & Hardness Analysis Module |
 | Solved potential crash when performing zoom on roughness chart diagram. This function is now disabled |  |
| Particle & Pore Analysis Module |
 | Values are now copied correctly from analysis resut dialog (Grain and Roughness) |  |
| Batch Processing Module |
 | Fixed errors in ActiveReporter HTML preface templates delivered with SPIP |  |
 | Fixed error in ActiveReporter parsing of HTML templates when two SPIPControl objects were placed with no characters between them |  |
| Imagemet Explorer Module |
 | IMExplorer does not need to be restarted in order to show the newly added categories in the IMFinder category listbox. |  |
|
| SPIP™ v. 4.5.0 (2007-06-20) |
| Basic Module |
 | SPIP has gone online. With the new SPIP Online pane users can: be notified whenever a new free update is available, easily learn from tutorials, directly search for features and revisions online and learn more about the modules in SPIP. |  |
 | Implemented multi selection of AOI areas and improved selection handling to accommodate creation of complex masks |  |
 | Implemented multi selection of measuring tools |  |
 | New option for choosing a fixed size for the image ruler, for easier visual comparison of images |  |
 | Microsoft Vista compatible |  |
 | Operation on curve zooms are now limitted to the zoom range rather than the full source curve, making it easier to perform, e.g., a local curve fit. |  |
 | Corrected situation where not all pixels with values outside histogram markers are set to void pixels on demand |  |
 | Corrected clip outside color boundaries function to not modify other pixels |  |
| Calibration Module |
 | Corrected interchanged bottom and top width measurements in critical dimensions for single profile measurements |  |
| Particle & Pore Analysis Module |
 | New optional automated calculation of detection level in Grain/Pore Analysis threshold mode |  |
 | Nearest neighbor analysis with output in histograms and tabular text format |  |
 | Grain/Pore numerical results in tabular display are now shown with their units |  |
 | Corrected wrong handling of AOI in grain/pore analysis |  |
| 3D Visualization Studio Module |
 | Possible to switch between Perspective and Orthographic projection |  |
 | Fixed potentially non-smooth 3D Animation playback caused by change in resolution |  |
| Force Curve Analysis Module |
 | Implemented detection of Snap-in Force |  |
 | Force Curve batch processing results shown in tabular diplay |  |
 | Corrected missing second curve in zoom of Force vs. Separation curves |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Single point spectroscopy navigation tool implemented |  |
|
| SPIP™ v. 4.4.11 (2007-05-08) |
| Basic Module |
 | Calculation of Void- and Material Area for profile curves |  |
 | Updated SDF reader to support files produced by MTS Nano Indenter |   |
 | Fixed drag/drop of files from Outlook |  |
 | Corrected reading of X-Offset value from BCR file |   |
 | Corrected problem with average profile calculation and visualization when points per nm is different in X and Y |  |
| Calibration Module |
 | Corrected error when applying "Fourier" followed by "Unit Cell and Calibration" |  |
|
| SPIP™ v. 4.4.10 (2007-03-05) |
| Basic Module |
 | Corrected reading of Z axis unit in PSIA files |   |
 | NanoScope file reader no longer skips first image (error introduced in SPIP 4.4.9) |   |
| Force Curve Analysis Module |
 | Implemeted PNI force curve support |   |
 | Corrected zoom function for Force curve windows |  |
|
| SPIP™ v. 4.4.9 (2007-02-26) |
| Basic Module |
 | Fixed error that prevented dongle sharing (introduced in v. 4.4.8) |  |
 | Corrected inactive "Define Image Zero Level by Active Cursor" in Histogram |  |
|
| SPIP™ v. 4.4.8 (2007-02-08) |
| Basic Module |
 | Implemented support for Dektak 1D file format |   |
 | New command line feature: "-f" will bring SPIP window to the front |  |
 | Improved mangement of SPIP application´s "Current directory" to prevent locking folders |  |
 | Corrected scaling of NanoScope AFM IV Curves |   |
 | Measure tools, IV curve tools, and AOI tools are now easier to place near image border |  |
 | Corrected error showing "Fixed Color Range" when loading images with conflicting range |  |
 | NanoNis files with scan direction "up" are no longer flipped vertically |   |
 | Corrected setting of color range in image for custom color bars |  |
 | Fixed error in Z units of exported Omicron SCALA files |   |
| Roughness & Hardness Analysis Module |
 | Corrected "infinite loop" error in roughness calculation on flat images |  |
| 3D Visualization Studio Module |
 | Fixed error in saving Scale Mode in 3D View Settings |  |
| Imagemet Explorer Module |
 | Potential “Hang up" problem on XP and Windows 2000 has been fixed |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | IV curve tool modified so that the average calculation is only performed on non-void data points. If all points in a plane are void then the average value is set to void. |  |
|
| SPIP™ v. 4.4.6 (2007-01-11) |
| Basic Module |
 | Calculation of length in Line Measure tool corrected |  |
|
| SPIP™ v. 4.4.3 (2006-12-15) |
| Basic Module |
 | Zoom windows now includes a calculated "Trace Time", "Retrace Time", and "Time per Image". |  |
 | Poly line profiling moved fromCalibration module to Basic module |  |
 | Removed display of a weak vertical "dotted line" displayed in the centre of an image (introduced in version 4.4.2). This incorrect line had no influence on the image processing, and had only a visual effect |  |
 | Corrected detection of line structures for images where the x and y pixel size differs |  |
| Roughness & Hardness Analysis Module |
 | Calculating roughness on image with uneven size no longer causes error |  |
| Imagemet Explorer Module |
 | Drag & drop operation from Outlook into SPIP main is now possible. |  |
 | Reporter now reports correctly on results from Finder |  |
| Force Curve Analysis Module |
 | Implemented reading of PSIA Force .txt files with Force values in 5th column (normally 4th column) |   |
|
| SPIP™ v. 4.4.2 (2006-11-21) |
| Basic Module |
 | Improved support for RHK .sm3 files |   |
 | Fixed error in reading of Hysitron files introduced in v. 4.4 |   |
 | Fixed potential crash when duplicating multi-curve window |  |
| Extended Fourier Analysis Module |
 | Image name of Inverse FFT now changes when source image changes |  |
| Roughness & Hardness Analysis Module |
 | Showing detected hardness indent inclusive pileup area when set on |  |
 | Corrected display of Hf parameter in Hardness Analysis detailed window |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Fixed missing or incorrect axis units in a Zoom window of a Curve Window generated by "Average All IV Curves" |  |
 | Corrected error when creating an average IV curve using "Average All IV Curves", closing the window and re-creating this curve |  |
 | Fixed error in calculation of average IV curves: Void pixels were included in the calculation |  |
 | Corrected error: IV markers could be placed outside the image boundary |  |
|
| SPIP™ v. 4.4.1 (2006-11-10) |
| Basic Module |
 | Crosshair- and multi-profiles and ROI now available in FFT images |  |
 | Fixed error in calculated values for curves after subtracting fitted curve or changing units from the "Graph Properties" window |  |
 | Multi-curve windows now show curves (Error introduced in 4.4) |  |
 | Ruler is now also available for zoom windows |  |
|
| SPIP™ v. 4.4 (2006-11-09) |
| Basic Module |
 | Added Line, Circle/Ellipse and Polygon measure Tools, measureing length, width, height, area, volume etc. |  |
 | Added a horizontal ruler (dimension line) for 2D images |  |
 | Image Calculator introduced for doing pixel-wise algebraic operations on images |  |
 | Improved support for NanoScope V7.0 files |   |
 | Corrected scaling of Z data from Shimadzu files |   |
| Roughness & Hardness Analysis Module |
 | Measure Vickers, Contact, and Indentation Hardness for your indentation experiments by a single mouse click |  |
 | Fixed Roughness Analysis Parameters dialogue. The OK and Cancel buttons were not displayed in this dialogue when running on a Japanese Windows |  |
| Batch Processing Module |
 | Extended ActiveReporter with support for HTML templates/reports |  |
 | Fixed error where the Sniffer together with Auto.batch might trigger an infinite loop of loading, processing and outputting images |  |
| Filter Module |
 | Added Erosion and Dilation to Filters menu |  |
| Imagemet Explorer Module |
 | Synchronization is only done for new files that do not exist in the database or have been modified |   |
 | Populating the contents of large multi image files is done much faster |   |
|
| SPIP™ v. 4.3.4 (2006-10-04) |
| Basic Module |
 | Enabled Batch Processor to save spectroscopy data in SCALA PRO file format. |   |
 | Added support for CITS data in RHK .sm3 files |   |
 | Corrected writing topographic data to ASCII file so that each row is written into one line |   |
| Batch Processing Module |
 | Fixed problems in Japanese version with items that reference files (e.g. ActiveReport) |  |
| Imagemet Explorer Module |
 | Multi image files can now be expanded (fix of error introduced in 4.3.3) |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Added option to generate spectroscopy (line) image from volume image |   |
|
| SPIP™ v. 4.3.3 (2006-09-13) |
| Basic Module |
 | Implemented TNW file format |   |
 | Fixed error when performing several different calculations involving FFT |  |
 | Undo function now also recovers title caption |  |
 | Solved problem with display of japanese translation on Windows 2000 |  |
| Extended Fourier Analysis Module |
 | Corrected potential crash when executing Correlation Averaging followed by Extended Fourier. |  |
| Imagemet Explorer Module |
 | Navigation in ImageMet Explorer folder pane made easier as the pane keeps focus after selecting a new folder |  |
|
| SPIP™ v. 4.3.2 (2006-08-04) |
| Basic Module |
 | Added two extra sets of cursors for use with the single profiling tools. |  |
 | Included support for a new variant of the PicoScan file format. |   |
 | User defined Y offset is now included when calculating Average and Std. Dev., and when copying to a single profile window. |  |
 | The Sniffer now also detects new files in sub-folders |  |
 | Inserted missing Japanese translation of View Settings |  |
 | Fixed scaling error on profiles for certain images. |  |
 | Alignment of multi-curves in horizontal and vertical direction (when pressing "x" or "y") has been fixed. |  |
 | Corrected loading files having spaces in the file/path name, from the Heuristic File Importer into WordPad. |   |
| 3D Visualization Studio Module |
 | Asian characters are now handled in the 3D window |  |
| Imagemet Explorer Module |
 | Folders can now be renamed in ImageMet Explorer |  |
| Movie & Time Series Analysis Module |
 | Fixed error after deleting frames from a movie with 3D view enabled. |  |
|
| SPIP™ v. 4.3.1 (2006-07-11) |
| Basic Module |
 | "Auto correlation" function now available with Basic Module. |  |
 | Improved control of polyline output curves |  |
 | Now removing zoom box on curves when its zoom window is closed |  |
 | Corrected drawing new button icons for customised toolbars. |  |
 | Corrected reading of rectangular NanoNis files having lines/points switched around, leading to garbled data for rectangular images |   |
 | Corrected wrong Z scaling on NanoScope III images when Z sensitivity is negative |   |
 | Corrected license checking errors in "Operate with main image" commands |  |
| Imagemet Explorer Module |
 | Width values of columns in Detail view are now stored. |  |
| Force Curve Analysis Module |
 | Corrected the dy/dx unit in cursor view for Force curves. |  |
|
| SPIP™ v. 4.3 (2006-07-05) |
| Basic Module |
 | Japanese language version implemented. You can now choose between English and Japanese languaage user interface |  |
 | Implemented Hysitron file format (.hdf) |   |
 | Implemented new Pacific Nanotechnology Inc, PNI file format (.pni) |   |
 | Implemented Fogale file format (.tpo) |   |
 | Increased the hit-area arround the colorbar cursors, making it easier to move these. |  |
 | Implemented JEOL IV curve file format (.spc) |   |
 | New preferences dialog features:
- Improved layout
- New option: Reset View Settings to factory defaults
- New option: Reset "Don´t show again" settings |  |
 | Solved failure to open all selected files when opening multiple files from the plain open dialog |  |
 | Solved inactive Sniffer when using an empty disk folder as the sniffer folder |  |
 | PSIA files with reversed byte order are now read correctly. |   |
 | Corrected inactive "Show Integration" in histogram context menu |  |
 | Corrected possible calculation error of dy/dx in curves when units are of different types e.g. voltage and length |  |
| Particle & Pore Analysis Module |
 | Corrected z-range display of "Local SD" and "Local Mean" windows produced by Grain Backgound Filter |  |
| Batch Processing Module |
 | Solved Batch processing problems with specifying Settings for "Filter Specific", "Fourier Filter Specific", "Grain Analysis Specific", and "Plane Correct Specific" |  |
| Filter Module |
 | Activated bordermode handling for Gaussian smoothing filters |  |
| Imagemet Explorer Module |
 | Improved ImageMet Explorer performance. You can now browse you files in thumbnail view much faster. |  |
 | Activated drag drop function from ImageMet Finder |  |
 | Automated update of browser file pane when creating/renaming or deleting files |  |
| Force Curve Analysis Module |
 | Corrected cantilever sensitivity to be displayed as V/nm instead fo nV/nm |  |
|
| SPIP™ v. 4.2.6 (2006-05-22) |
| Basic Module |
 | Reading and handling of z-offset of JEOL SPM files (.tif) |   |
 | Print dialog default margins now matching system locale |   |
| Calibration Module |
 | Corrected Incorrect "Top Width" in ISO 5436 display for "Entire Image" |  |
| Extended Fourier Analysis Module |
 | Corrected potential crash while performing threshold Fourier Filtering with "Show FFT Filtered" on |  |
 | Corrected potential crash when Fourier Filtering and the main image has changed size |  |
| Particle & Pore Analysis Module |
 | Adjusted slider min max range in "Segment Types and Limits" dialog to always reflect range of target segments, such that large border segments does not influence the range when border segments are excluded |  |
 | Solved writing to .grn result file which may stop after many writings |   |
| Batch Processing Module |
 | Solved Batch processing item "Plane Correct Specific" causing grain analysis to be performed |  |
 | Solved possible problem in including 3D images in Active Word Reports |  |
 | Solved incomplete 3D rendering in combination with the very first Auto-Run batch process |  |
 | Reactivated "Func List" button in Batch Processing Dialog for showing list of available batch functions |  |
 | Reactivated automated display of ASCII result file when batch processing force curves |  |
 | Corrected potential exception error when running active Force Curve reporting to MS Word files |  |
|
| SPIP™ v. 4.2.5 (2006-05-08) |
| Basic Module |
 | Space for axis text in curve window adjusted automatically when modifying font size. |  |
 | Default margin shown in print dialog now matching system locale. |  |
 | Corrected NanoScope File Reader to care of x,y aspect ratio different from 1:1 |   |
 | Solved change of x-offset value when reading curves saved in BCR format. |   |
 | Updating physical unit of connected cross section profile when loading images with different dimension type |  |
 | Activated simultaneous display of cursors in image when shown in cross section profiles |  |
 | Enabled turning off button for average profiling |  |
 | Fixed restoring most recent settings in "Save As" dialog |   |
| Calibration Module |
 | Implemented manual adjustment of calculated unit cell vectors by mouse dragging and by modifying the numerical length and angle of the vectors. |  |
| Correlation Averaging Module |
 | Solved potential crash when performing Correlation Averaging on non-even sized images |  |
| Roughness & Hardness Analysis Module |
 | When enabling parameters in the new Roughness grid dialog the selected parameter fields will be updated |  |
| Particle & Pore Analysis Module |
 | Contour center X,Y coordinates are now reported in nano-meter unit instead of pixels |  |
 | Solved writing to .grn result files, which could stop after processing many files |  |
| Batch Processing Module |
 | Corrected missing 3D images in Active Word Reporting |  |
|
| SPIP™ v. 4.2.4 (2006-04-03) |
| Calibration Module |
 | Improved lateral linearity calculation of images having an almost perfect lattice structure |  |
| Particle & Pore Analysis Module |
 | Preventing popup of Grain Result Dialog when the option is turned off |  |
| Imagemet Explorer Module |
 | Deletion of files in ImageMet Explorer made possible by clicking the Delete key |  |
| Force Curve Analysis Module |
 | Molecular Imaging (Agilent) PicoView force and spectroscopy curve file format (.mi) implemented |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Fixed incorrect scaling of Voltage, when exporting CITS volume images to the Scala Pro file format |   |
|
| SPIP™ v. 4.2.3 (2006-03-24) |
| Basic Module |
 | Molecular Imaging (Agilent) PicoView File Format (.mi) implemented |   |
| Roughness & Hardness Analysis Module |
 | New tabular reporting style for roughness parameters (spreadsheet like) |   |
| Particle & Pore Analysis Module |
 | New tabular reporting style for grain analysis parameters (spreadsheet like) |   |
| Batch Processing Module |
 | Fixed potential crash in HTML and Word reporting on Windows 2000 |  |
| Filter Module |
 | Fixed potential crash when opening Filter dialog on Windows 2000 |  |
|
| SPIP™ v. 4.2.2 (2006-03-17) |
| Basic Module |
 | Improved ease of AOI placement at image boundaries |  |
 | Fixed incorrect handling of "last" in command line options used by Omicron Matrix instruments |   |
| Particle & Pore Analysis Module |
 | Enabled Auto Detection of grains, when Area of Interest is changed |  |
 | Corrected handling of AOI in grain analysis for images with different x,y resolutions |  |
| Batch Processing Module |
 | Corrected inactive Batch Processor |  |
 | Corrected non-processed line-wise plane correction |  |
|
| SPIP™ v. 4.2.1 (2006-03-15) |
| Basic Module |
 | Corrected possible missing curve when putting calculated mean curve from Multi Curve Window to Single Curve Window |  |
 | Enabled Sniffer to use Root directories, for example C:\ etc. |  |
| Batch Processing Module |
 | Solved problem when opening multiple files from the plain File Open dialog |   |
| Filter Module |
 | Corrected potential crash when filtering 1D curves. Problem introduced in version 4.2 |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Solved potential crash when Exchanging CITS image with Main Image |  |
|
| SPIP™ v. 4.2 (2006-03-09) |
| Basic Module |
 | Mutiprofile averaging quality improved by increasing number of points |  |
 | Suport for multi byte characters (Unicode) making it possible to handle for example Japanese and Chinese characters |  |
 | Optional button Icon size of 16x16, 24x24 or 32x32 points |   |
 | Highligth of color marker when used for defining threshold value in for example Grain Analysis |  |
 | Optional to set colorbar contrast adjustment to Area of Interest (AOI) |  |
 | New rotation buttons for 90 degree clockwise or counter clockwise |  |
 | New user interface design with more appealing button icons making it easy to identify relevant functions |  |
 | Heuristic file reader, corrected y-mirroring for 16 bit images |   |
 | Fixed axes label placing problem introduced in Version 4.0 |  |
 | Corrected missing updates of Area and Volume parameters in Histogram after plane correction |  |
 | Suporting z-unit and z-scaling for ADE Phaseshift confocal or intensity images |   |
| Calibration Module |
 | Corrected potential missing updates of width and slope parameters in ISO 5436 based measurements |  |
| Roughness & Hardness Analysis Module |
 | Optional rose plot of Correlation length as function of angle |  |
 | Corrected missing Shw (Mean Half Wavelength) calcualtion when all other Fourier based parameters are turned off |  |
| 3D Visualization Studio Module |
 | Texture colors corrected for combined property images having all Z values negative. |  |
| Batch Processing Module |
 | HTML reporting now showing relevant parameters with 7 or significant digits |  |
 | Corrected missing Histogram in Auto Run mode when part of the AutoRun.Batch file |  |
| Filter Module |
 | Outlier filter dialog made available from main filter dialog |  |
 | Median Filter now with modification percentage as input. Define how many of the worst outlier you want to correct and observe the result while changing the value. |  |
 | Improved Filter Module by making it more powerful but also easier to use |  |
 | Corrected Border Mode behaviour for ISO 13565-1 and Robust Filter |  |
| Force Curve Analysis Module |
 | Resolved potential crash occuring when Average is pressed in Force Curve Dialog with only one force curve open |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Implemented export of CITS volume image to the Omicron SCALA file format |   |
 | Corrected reading of JEOL CITS volume images having more than 128 points per IV curve |   |
|
| SPIP™ v. 4.1.8 (2006-01-27) |
| Basic Module |
 | Ambios Void Pixel support |   |
 | JPK image files: Corrected volt unit for Volt Amplitude curves and extracted extra parameters into the image description field |   |
 | Corrected X coordinates of ASCII exported data from multi curve windows |   |
| Force Curve Analysis Module |
 | JPK force curve files: Using smoothed height signal |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Implemented writing of entire CITS volume data to ASCII files |   |
 | Omicron Matrix files: Fixed read error of CITS data when CITS was only done in the forward scan direction |   |
|
| SPIP™ v. 4.1.7 (2006-01-04) |
| Extended Fourier Analysis Module |
 | Activated Inverse FFT filter from context menu of Fourier image |  |
| Force Curve Analysis Module |
 | Corrected axis labeling for PSIA, Park and Topometrix force curves |   |
 | Corrected deflection scaling of NanoScope force curves |   |
|
| SPIP™ v. 4.1.6 (2005-12-13) |
| Basic Module |
 | Improved Plane correction for images with extreme slopes |  |
 | Added suppurt for Hitachi FineTech .afp profile files |   |
 | Enabled use of upper case letters when saving files |   |
|
| SPIP™ v. 4.1.5 (2005-11-29) |
| Basic Module |
 | Improved support for NanoScope friction files |   |
 | Improved support for RHK multi image files |   |
 | Fixed error in calculation of Void Volume in histograms |  |
| Batch Processing Module |
 | Fixed problem printing from batch processing |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Fixed problem reading CITS data from Omicron Matrix file format |   |
|
| SPIP™ v. 4.1.4 (2005-11-22) |
| Basic Module |
 | Corrected visualization of x-average curve during rotation |  |
 | Corrected potential potential crash when selecting cross hair profiling |  |
| Batch Processing Module |
 | Corrected print function from batch processing |  |
|
| SPIP™ v. 4.1.3 (2005-11-18) |
| Basic Module |
 | Moving of poly line points made easier, use Shift + mouse movement |  |
 | Arrow directions used for indication of time direction for Veeco CAFM´s IV recordings corrected for Veeco CAFM´s IV recordings corrected for negative voltage ramps |  |
 | Labels defined for all curves |  |
 | Mouse position coordinates in status field now written including units |  |
 | For Fourier windows the wavelength and amplitude at the current mouse position is now written in the status field |  |
 | Improved Plane Correction "Quality Mode" |  |
 | Synchronized Zoom activates zooming for all image windows of same size when selected |  |
 | Synchronized Profiling activates profiling for all image windows of same size when selected |  |
 | Corrected poly line units |  |
 | Reestablished delete key function for Poly Line curves for deletion of individual points |  |
 | Solved potential error when saving poly line graphs |  |
 | Corrected "Z-Offset Method", "Bearing Height to Zero" in "Plane Correction" Dialog |  |
 | Solved error occurring when loading images and having both Plane correction "Apply when Loading" and "Inside Area of Interest" on |  |
 | Corrected saving of DigitalSurf .sur files when x,y units are different from nanometer |   |
| Particle & Pore Analysis Module |
 | In Threshold mode, the active color marker for changing the threshold value is now highlighted |  |
 | Added labels to grain histogram axes |  |
 | Mouse selection/modification of Grain segment enabled for contour image also without having the segment image open |  |
 | Include Border elements setting can now be saved/recalled |  |
| 3D Visualization Studio Module |
 | 3D, Solved possible error messages when using 3D low acceleration mode on ATI Radeon graphics cards |  |
| Filter Module |
 | Filter, made filter functions available for Poly Line graphs |  |
| Imagemet Explorer Module |
 | ImageMet Explorer, Description column in the file list pane (details view) is now kept up-to-date |  |
|
| SPIP™ v. 4.1.2 (2005-11-03) |
| Basic Module |
 | Support for Veeco AFM Tuna conductivity images and curves |   |
 | Corrected potential calculation error of Multi Curve Window average |  |
 | Multi curve ASCII export enhanced with 7 digit precision |   |
 | Multi curve export, with corrected offset values |   |
| Particle & Pore Analysis Module |
 | Allowing threshold values outside image boundary |  |
 | Corrected such that preprocessing does not modify input image |  |
| Batch Processing Module |
 | Corrected repetition of preface template in batch processes using Word document as output |  |
 | Corrected potential for wrong 3D images in word based reports when running large batch processes |  |
| Imagemet Explorer Module |
 | ImageMet Explorer Load time shortened further |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Corrected unit when saving CITS images to ASCII |   |
|
| SPIP™ v. 4.1.1 (2005-10-28) |
| Basic Module |
 | New option for turning off linear interpolation when drawing in 2D |  |
 | Faster 2D drawing due to optimized interpolation algorithm |  |
 | Corrected export of multi curves by adding correct X and Y offset values |   |
 | Corrected reading of Void Pixels from ADE PhaseShift images |   |
| Particle & Pore Analysis Module |
 | Improved detection speed for watershed algorithm |  |
| 3D Visualization Studio Module |
 | Corrected potential for wrong result when saving large 3D images to Word Reporter, clipboard or file |  |
| Batch Processing Module |
 | Writing to Omicron Scala data format from Batch processes |   |
| Imagemet Explorer Module |
 | Tip characterization and linearity results from multi image files can now be stored for the individual images into the database |  |
 | Shorter load time |  |
 | Added Delete key |  |
 | Easier resizing of thumbnails |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Corrected displaying of images when number of window pixels are lower than in the source image |  |
 | Corrected color scale adaptation when changing the voltage dimension |  |
 | Corrected export of selected CITS Voltage index image to Omicron Scala format |   |
|
| SPIP™ v. 4.1 (2005-10-18) |
| Basic Module |
 | New Area of Interest (AOI) selection tools:
Create simple and complex AOI and combine with e.g. plane correction and roughness analysis |  |
 | Improved Plane Correction Dialog:
New easy to use auto modes for Quality or Speed optimization and Custom mode for advanced users |  |
 | Improved Plane Correction Dialog: New technique for automated handling of steps, pits and grains to assure optimal flattening |  |
 | Improved Plane Correction Dialog: Save and Recall of settings, which can be retrieved from batch processes |  |
 | Undo capability for Void Pixel manipulation |  |
| Calibration Module |
 | Corrected position of height indicators for critical dimension calculation based on ISO 5436 |  |
| Batch Processing Module |
 | Can now process individual images or curves from multi data files |  |
 | Option rejection of non-topographic images |  |
 | Recall of specific plane correction settings |  |
 | Function for extending filename with an incremental number, such that results from the same image processed in different ways can be stored in different result files |  |
 | Global grain analysis results, such as number of segments and coverage percentage, can now also be included in HTML reports |  |
| Imagemet Explorer Module |
 | Handling and display of ´multi data files´ making it easy to navigate through sub-images or curves contained in the same file |  |
 | Detailed view for display and selection of individual thumbnails for sub-images and sub-curves |  |
 | Compact view of multi data files with ´folder thumbnails´ showing the number of data objects |  |
 | Database entries for sub images and sub curves where results automatically can be stored and retrieved |  |
| Force Curve Analysis Module |
 | Re-sampling JPK force curve data to obtain equidistant height values |  |
 | Reading of TopoMetrix Force curves in .txt format |   |
 | Corrected missing Force value fields in ASCII based reports |  |
|
| SPIP™ v. 4.0.9 (2005-09-30) |
| Extended Fourier Analysis Module |
 | Correction for potential crash when perforing fourier filtering from batch processes |  |
| 3D Visualization Studio Module |
 | Corrected error when exporting 3D animations to .mpeg or .avi formats |  |
| Force Curve Analysis Module |
 | Modified reading of PSIA force curves to handle more than 256 points and implemented re-sampling of data to assure equidistant height values |  |
 | Corrected y-scaling for specific force curve file formats |  |
|
| SPIP™ v. 4.0.8 (2005-09-20) |
| Basic Module |
 | Corrected y-scaling for specific curve file formats |  |
| Extended Fourier Analysis Module |
 | Enabled 1D high resolution FFT (previously the calibration Module was required) |  |
 | Removed limit size for unit cell so that it now can exceed 1 mm |  |
| Particle & Pore Analysis Module |
 | Improved detection accuracy in watershed algorithm |  |
| Batch Processing Module |
 | New Auto Run function, which allow you to process and display data windows in a customized way every time a new file is opened |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Corrected z-unit for CITS gradient images |  |
| Plug-In Interface Module |
 | Corrected Get functions to reflect most recent modification of image data before displaying |  |
|
| SPIP™ v. 4.0.7 (2005-08-24) |
| Basic Module |
 | Handling void pixels when zoomimg |  |
 | .bcrf format now supporting non-Intel floating point format (little Endian) |   |
 | Supporting new Omicron Matrix 1.1 file format |   |
| Extended Fourier Analysis Module |
 | New Save/Load function for user defined filters, which can also be activated from the Batch Processor |  |
| Particle & Pore Analysis Module |
 | New Parameter, "Mode Corrected Elements", which estimates the true number of detected segments by calculating the number of particles in clustered segments assuming a constant segment area equal to the mode value of the area distribution histogram |  |
| 3D Visualization Studio Module |
 | Possible to save pictures larger than the screen, useful for creating high-resolution posters |  |
 | New productivity tool in 3D Animation dialog for setting a specific parameter identical in all movie frames, for example z-scale or background color |  |
| Batch Processing Module |
 | Now supporting Fourier Band filters |  |
 | Word ActiveReporter: Updating MS Word fields, such as date, author and filename |  |
| Force Curve Analysis Module |
 | Base Line correction algorithm tuned for handling highly distorted curves |  |
|
| SPIP™ v. 4.0.6 (2005-07-13) |
| Basic Module |
 | Support for opening Omicron data from single files, which are part of a larger file chains |   |
 | Corrected automated handling of unit conversion for curve windows introduced in version 4.0.5 |  |
| Calibration Module |
 | When aligning images the unknown areas are defined as Void Pixels |  |
| 3D Visualization Studio Module |
 | Corrected activation of color scale when loading new animation file |  |
| Force Curve Analysis Module |
 | Corrected slope calculation error introduced in version 4.0.5 |  |
 | Corrected Baseline correction function |  |
|
| SPIP™ v. 4.0.5 (2005-06-29) |
| Basic Module |
 | Duplication of cross section lines in Multi Line Profiling mode |  |
 | RHK .sm3 format implemented |   |
 | Corrected reading of temporary license files |  |
 | Corrected calculation of X- and Y-range in Digital Surf formats |   |
| Calibration Module |
 | Added automated measurement of Critical Dimensions including length and side wall angel to the ISO 5436 method |  |
| 3D Visualization Studio Module |
 | Possible to define origin of coordinate system in 3D images |  |
 | Corrected error for 3D batch processing |  |
| Batch Processing Module |
 | Corrected file save problems for Omicron Matrix files from Batch processes |   |
|
| SPIP™ v. 4.0.4 (2005-06-21) |
| Basic Module |
 | Corrected reading of 8 bit tiff files |   |
| 3D Visualization Studio Module |
 | Improved auto resolution and preview |  |
 | Improved read/write of settings |  |
| Force Curve Analysis Module |
 | Force curve analysis made more robust agaist noise |  |
 | Reading of new NanoScope force curve files |   |
|
| SPIP™ v. 4.0.3 (2005-06-13) |
| Basic Module |
 | Corrected reading of Park format |   |
|
| SPIP™ v. 4.0.2 (2005-06-09) |
| Basic Module |
 | Added save to Omicron Scala format |   |
| 3D Visualization Studio Module |
 | Corrected reading (recall) of 3D settings in .3dp format |  |
|
| SPIP™ v. 4.0.1 (2005-05-30) |
| 3D Visualization Studio Module |
 | Corrected 3D rendering for various graphic cards |  |
| Imagemet Explorer Module |
 | Z-unit corrected for ImageMet Explorer |  |
|
| SPIP™ v. 4.0.0 (2005-05-26) |
| Basic Module |
 | New user interface concept using a View Settings Pane for all data windows. This gives you easy and detailed control of the image and curve appearances, scaling etc., and you can for example define your own color schemes. The View Settings Pane can be auto hided and docked so that it is always at hand. |  |
 | New Multi Line Profiling tool enabling you handle more profiles in the same window and study similarities in detail and calculate Mean or SD curves. You can even compare profiles from more images and synchronize their position so that differences between ´before´ and ´after´ images can be investigated. |  |
 | Optional use of Metric or US units |  |
 | Shimadzu: New supported SPM format |   |
| 3D Visualization Studio Module |
 | More view parameters, which give you even more control of the 3D surface rendering, now controlled from the new View Settings Pane |  |
 | New Window Pane for 3D animation making it easier to create animations in seconds just by a defining a few key images |  |
| Batch Processing Module |
 | New function for interpolating void pixels in Batch Processor |  |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | New tool for selecting and handling more IV curves in the same curve window |  |
 | Easy control of the voltage determining the current image from the CITS volume data, by use of the new View Settings Pane. |  |
 | Implemented d2I/dV2, dlnI/dlnV and dlnI/dV |  |
|
| SPIP™ v. 3.3.9 (2005-04-04) |
| Basic Module |
 | ADE Phase Shift: Reading Map files with images containing up to 20000 columns (increased from 4094 |   |
 | Ambios .iii: Interpreting 16 bit integers as unsigned, to correct scaling of large range images. |   |
 | Molecular Imaging: Reading of multiple force curves |   |
 | Omicron Matrix: Command line support for multiple sub-images from same bricklet |   |
 | Setting y-unit for y-average profiles correctly |  |
| Particle & Pore Analysis Module |
 | Corrected graying out the histogram key in the Grain Analysis Dialog |  |
| Force Curve Analysis Module |
 | Veeco/AFM: Adapted reading of cantilever spring constant to newer Veeco format, used for force curve analysis. |   |
|
| SPIP™ v. 3.3.8 (2005-03-21) |
| Particle & Pore Analysis Module |
 | Preventing potential crash when right clicking in grain histograms |  |
| 3D Visualization Studio Module |
 | Preventing potential crash in 3D animation after play, stop and play sequence |  |
|
| SPIP™ v. 3.3.7 (2005-03-11) |
| Basic Module |
 | Implemented variable z-unit in .bcr and .bcrf files |   |
 | Veeco PicoForce: Adjusted reading of Veeco PicoForce version 0x06 format |   |
 | JEOL SPM: Corrected z-scaling problem |   |
 | Solved Printing SPIP Screen problem occurring on some computers |  |
 | Solved Image Print problem occurring on some computers |  |
 | Corrected Z-unit modification in image property window when using non length units |  |
 | Corrected Z-scale of JEOL tiff files |  |
 | Omicron Scala: Corrected Z-scaling for spectroscopy data |  |
| Extended Fourier Analysis Module |
 | Corrected Z-unit for Fourier images and curves not in simple length scale |  |
| Roughness & Hardness Analysis Module |
 | Optional display of selected roughness parameters in all topographic image windows. This enables for example simultaneous monitoring of roughness parameters for original and low pass and high pass filtered images. Optional use of inch and mil units. |  |
 | New parameter: Scl20, Correlation length at 20%. The horizontal distance of the area autocorrelation function that has the fastest decay to 20%. |  |
 | New parameter: Scl37, Correlation length at 37% (~1/e). The horizontal distance of the area autocorrelation function that has the fastest decay to 37%. |  |
 | New parameter: Str37, Texture Aspect Ratio, at 37%. The ratio between the fastest and slowest decay to 20%. Expresses the isotropic property. |  |
 | New parameter: S2A, the projected surface Area |  |
 | New parameter: S3A, the effective 3D surface Area |  |
 | New parameter: Str20, Texture Aspect Ratio, at 20%. The ratio between the fastest and slowest decay to 20%. Expresses the isotropic property |  |
| Particle & Pore Analysis Module |
 | Added Save/Recall of settings. This enable fast retrieval of setups for specific applications and bath processing |  |
 | Added Mode and Median statistical values for all grain parameters |  |
| Batch Processing Module |
 | Added selection of Grain specific settings. |  |
 | Added selection of 3D specific view settings |  |
 | Added more roughness parameters for reporting by the Active Word Reporter. |  |
 | Added more grain parameters for reporting by the Active Word Reporter |  |
| Force Curve Analysis Module |
 | JPK: Implemented support for .out force curve files |   |
| CITS Continuous Imaging Tunneling Spectroscopy Module |
 | Omicron Matrix: Added CITS support |   |
|
| SPIP™ v. 3.3.6 (2005-01-12) |
| Basic Module |
 | Ambios: New supported .amb format |   |
 | NanoSurf: New supported .nid format |   |
 | Veeco Nanoscope: Added support for Friction curves |   |
 | Veeco Nanoscope: Added Note and DataType fields to image description |   |
 | Corrected jpeg and tiff format saving error introduced in version 3.3.5 |  |
| Extended Fourier Analysis Module |
 | Fourier: Normalizing z-values by number of pixels |  |
| Batch Processing Module |
 | Enabled .bmp files for batch processing |  |
 | Assuring ".asc" extension when saving data files in ASCII format |  |
| Filter Module |
 | Increased filter kernel size for 1 dimensional filters from 255 points to 4000 points |  |
|
| SPIP™ v. 3.3.5 (2004-12-20) |
| Basic Module |
 | Added more significant digits to curve Cursor values |  |
 | AutoFocus: Corrected Z-scaling |   |
 | Burleigh: Correcting z-scaling for file version 5.0 |   |
 | Ambios: New supported format |   |
 | DME .mif files: Handling images with zero y-length by setting y-unit to ´pixel´ |   |
 | PSIA: Corrected potential crash error when reading tiff based force curve files |   |
 | Corrected potential auto tiling problem when setting preferred window size larger than the program window |   |
| Extended Fourier Analysis Module |
 | Corrected potential error when setting Fourier dialog to show Fourier image in 3D |   |
| Particle & Pore Analysis Module |
 | Threshold step incremental when using spin buttons set to 0.001 of full z-range instead of 0.01 for finer user control |  |
 | Undo function added to filter functions |  |
| Batch Processing Module |
 | Zoom function added to Batch to enable automated analysis of sub images |  |
| Filter Module |
 | Median Filtering: Solved potential crash when running filter on image which has increased in size |   |
|
| SPIP™ v. 3.3.4 (2004-12-02) |
| Basic Module |
 | Fixed a problem introduced in version 3.3.0 that disabled the use of the arrow keys to move a “Line-cross section” and the cursors in the coordinate window |  |
| 3D Visualization Studio Module |
 | Fixed "Unable to set pixel format" error in 3D on Intel graphics adaptors |  |
|
| SPIP™ v. 3.3.3 (2004-11-25) |
| Basic Module |
 | Optional connection of color markers to Histogram Markers for more intuitive height, area and volume measurement |  |
 | Histograms can optionally be shown by adopting the colors of the image color bar |  |
 | Added reset function for color bar markers in image and color bar editor by Home key |  |
 | Corrected reading of x,y scale information from JPK files |  |
 | Corrected tri-state behavior of oblique marker used for showing detected lattice / Unit Cell |  |
| Extended Fourier Analysis Module |
 | Better performance when performing Inverse FFT filtering by color markers |  |
| Roughness & Hardness Analysis Module |
 | Optional connection of color markers to Abbott Curve Markers for more intuitive measurement |  |
 | Abbott curves can optionally be shown by adopting the colors of the image color bar |  |
| 3D Visualization Studio Module |
 | Stopping 3D animation on closing 3D dialog or 3D window |  |
|
| SPIP™ v. 3.3.2 (2004-11-11) |
| Basic Module |
 | Corrected license validation problem, which may force the program into demo mode after the expiration of the maintenance service period |  |
|
| SPIP™ v. 3.3.1 (2004-11-04) |
| Basic Module |
 | Notification dialog with information on accelerator keys assigned to navigation keys (arrows) |  |
| 3D Visualization Studio Module |
 | Fixed crash for images larger than 1024x1024 pixels when autotiling is on in 3D Visualization Studio |  |
| Imagemet Explorer Module |
 | Corrected editing of file names/opening of files in Imagemet Explorer´s file list view |  |
| Plug-In Interface Module |
 | Fixed wrong path to IMinterface.dll in Visual C++ 6 Plug-in wizard resulting in build error |  |
|
| SPIP™ v. 3.3 (2004-10-27) |
| Basic Module |
 | Added utilities for controlling the size of curve and image windows and defining your favorite window sizes |  |
 | Possibility of creating your own toolbars, so that you can get easy access to your most frequently used commands |  |
 | Choose between different user interface styles (e.g. XP and Microsoft Office 2003) |  |
 | Plane Correction: when performing line wise correction in "AOI Only" the border mean level is preserved |  |
 | The Rotation dialog now has an option for preserving the original size rather than adding pixels to include the corner pixels |  |
 | Optional duplication of the main window when loading new images |  |
 | Profile zooming window is now updated automatically simultaneously with its parent profile window |  |
 | Void pixels are now invisible in profile windows |  |
 | Possibility to deactivate modules, helping you to decide for the right module combination before purchasing |  |
 | Omicron SPM Matrix format implemented |   |
 | Nanonis GmbH .sxm format implemented |   |
 | GFMesstechnik .fd3 format implemented |   |
 | DME .mif implemented |   |
 | A.P.E. Research .dat format implemented |   |
 | Oxford .wat format implemented |   |
 | NanoFocus .nms, .oms format implemented |   |
 | Handling of JEOL TIFF file problem occurring when using Windows XP SP2 |  |