| SPIP™ v. 6.0.14 (2013-05-23) |
| Basic Module |
 | The image file format for Park Systems new NX10 and NX20 SPMs has been implemented |   |
 | The LEXT file format for Olympus laser confocal microscpoes has been implemented |   |
 | User defined color scale limits now works as designed resulting in correct image contrast |  |
 | Tiff files with non square pixels are now displayed correctly. XY axis units are shown as "arbitrary" |   |
 | Fixed occasional incorrect color in the image zoom navigation overlay |  |
| Correlation Averaging Module |
 | Fixed crash when attempting to cross correlate two images of different size |  |
| Particle & Pore Analysis Module |
 | Erroneous scaling of Particle&Pore Analysis histograms has been fixed |  |
| Batch Processing & Reporting Module |
 | Correct behavior of the Void Pixels Batch item in case the current image has non-nano units is now ensured |  |
| Force Curve Analysis Module |
 | Reverted JPK force curves are now displayed right |   |
 | Parsing of NanoSurf force volume files have been corrected |   |
|
| SPIP™ v. 6.0.13 (2013-01-21) |
| Basic Module |
 | Resetting color clip markers when using "Crop to AOI", "Copy Data to Main", Dilate, Erode and Void Pixels Clear |  |
 | Preventing crash when using "Copy Data to Main" |  |
|
| SPIP™ v. 6.0.12 (2013-01-11) |
| Basic Module |
 | Correcting crash when using "Become Main" before use of Fourier |  |
|
| SPIP™ v. 6.0.11 (2013-01-10) |
| Basic Module |
 | Histograms can now be saved and loaded again, still being displayed as SPIP histograms |  |
 | Export of histograms to .asc will now produce a file with x values corresponding to bin centers and y values to bin heights |  |
 | Fixed failure to read some Asylum force volume map files |   |
 | Fixed database error occuring sometimes for non administrator users when starting IMExplorer |  |
 | Nanonis .3ds format: Corrected x,y units. Data unit for second spectroscopy channels is now always volt |   |
| Extended Fourier Analysis Module |
 | Avoiding conflicts and potential crash when Fourier output windows are defined as Main window |  |
| Roughness & Hardness Analysis Module |
 | The points, Smr1 and Smr2, used for the calulcation of Spk, Svk, and Sk parameters from the Abbott curve are now also reported |  |
| 3D Visualization Studio Module |
 | Adjusted default View Settings (surface position and rotation) for 3D display |  |
| Batch Processing & Reporting Module |
 | Fixed crash occuring when an ordinary image loaded in a force curve analysis Batch sequence |  |
 | Fixed missing calculated unit cell parameters in Active reports in Batch Process sequences containing Calibrate ## items |  |
| Force Curve Analysis Module |
 | Implemented support for JPK .jpk-qi-image file format (16 and 32 bit) |  |
 | Corrected interpretation of Nanosurf force volume data files |   |
|
| SPIP™ v. 6.0.10 (2012-11-27) |
| Basic Module |
 | Added multi-channel support for Createc files in compressed format |   |
 | Implemented the AFM Workshop format, .wsf |   |
 | Interpolating void pixel areas when performing Fourier analysis and Auto Correlation (making use of Fourier) |  |
 | Modified cursor read out to allow writing outside the curve drawing region and prevent clipped text |  |
 | Fixed location of Curve Fitting formula to the top of the curve window. |  |
 | Corrected Color Clip Marker positions for image with z-range less than 1 nm |  |
| Extended Fourier Analysis Module |
 | Corrected "Cursors on Peaks" in Fourier curves to show the most dominant peaks in order of appearance |  |
| Roughness & Hardness Analysis Module |
 | Corrected calculation of the Surface Bearing Index, Sbi |  |
| Batch Processing & Reporting Module |
 | Active reporting is now cropping screen dumps to cover the data windows only. |  |
 | Corrected active reporting Best Fit mode for image copies to respect fixed aspect ratios |  |
| Force Curve Analysis Module |
 | Supporting Force Volume and Force curve data in NanoSurf file format |   |
 | Corrected wrong Max Pull detection in situations where there is a very low push force |  |
| Plug-In Interface Module |
 | Modified File importer plug-in template for VS 2010 to compile in release mode without modifications |  |
|
| SPIP™ v. 6.0.9 (2012-10-04) |
| Basic Module |
 | Corrected error occurring when exiting SPIP on Windows XP computers |  |
|
| SPIP™ v. 6.0.8 (2012-10-02) |
| Basic Module |
 | Corrected installation problems |  |
|
| SPIP™ v. 6.0.7 (2012-10-01) |
| Basic Module |
 | Added parsing of 32 bit jpk image files |   |
 | Adjusted Agilent PicoView reader to handle missing force volume curves at the end of the image. |   |
 | Fixed parsing of certain of Agilent (.mi) force curve files |   |
 | Veeco/Bruker SSRM curves are now displayed as IV curves and not as force curves |   |
 | De-selection of all Shapes in images now occurs instantly. Before it could take a long time when there were many Shapes |  |
 | Fixed wrong line number indaction when printing a profile window |  |
 | Corrected status bar cursor position readout, which in special cases displayed the positions in fractions of pixels (in "pixel" mode) |  |
 | Left arrow key now again moves histogram cursors linked to the image color scale correctly |  |
 | When changing the number of bins in the Properties dialog of image/profile histograms the new histogram is now calculated over the entire Z range of the data set and not just over the displayed range (i.e. the X axis limits of the histogram) |  |
 | Histograms: Cursors no. 3, 4.. are now initially placed at the allowed discrete positions in histograms and not as before at positions which could be inside a bin |  |
 | Duplicating an image with a previously applied but closed Inspection Box would generate an Inspection Box in the duplicate image. This behavior has been annihilated |  |
 | Fixed issue that cross section profile decorations would remain on the Main image after a "Close All Except Main" operation |  |
 | Fixed crash in 16 bit color mode. Note: 16 bit color mode is only partially supported |  |
 | Fixed crash in autocorralation on images with uneven number of pixels in X or Y |  |
 | Fixed crash in the Calculator if calculation was executed with out any operand datasets |  |
 | Solved various issues with crash when the ribbon had been minimized |  |
 | Fixed crash which could occur because the current image view was in maximized mode |  |
 | Fixed non-responding SPIP when loading very large ascii files |   |
 | Fixed crash when undoing closing of a profile window and similar operations |   |
 | Corrected potential problem, causing the program to slow down when showing MDI windows in maximized mode and resizing the SPIP program window |  |
| Calibration Module |
 | Unit Cell & Calibration dialog: Typing in the "dx/dy" field does not activate "Apply" anymore |  |
 | Correcting an image with parameters Cx=0, Cy=0 and dx/xy = 0 is now prevented as the result could lead to crash in other parts of SPIP, e.g. roughness analysis |  |
| Roughness & Hardness Analysis Module |
 | Entering non-numeric values in the Hardness dialog "Tangent Height %" field is now not allowed, as this would lead to a crash |  |
| Particle & Pore Analysis Module |
 | The Built-In "Simple Threshold - Pore" settings in Particle&Pore Analysis is now actually configured for pores and not as previously for particles |  |
| Imagemet Explorer Module |
 | Fixed non-responding SPIP after browsing a zip file with ImageMet Explorer and then closing ImageMet Explorer |  |
| Force Curve Analysis Module |
 | Force Curve analysis settings are now read before analyzing force volume images also when the force curve dialog has not been opened |  |
 | Corrected Young’s modulus parameter mapping by DMT model on Force Volume images |  |
|
| SPIP™ v. 6.0.6 (2012-08-23) |
| Basic Module |
 | Corrected potential crash when ribbon is hidden, and closing all windows |  |
 | Corrected synchronization between red histogram cursor and the corresponding color scale clip maker which were off by one bin width in SPIP 6.0.5 |  |
|
| SPIP™ v. 6.0.5 (2012-08-22) |
| Basic Module |
 | Agilent PicoView Force Volume file format (.mi) has been implemented |   |
 | Implemented hitherto unsupported variant of the Wyko .OPD file format |   |
 | "Improved Auto Tiling in cases where the SPIP client area is very wide compared to its height |  |
 | Corrected collapsing Inspection Box on curves when one tries to move the Inspection Box outside the curve plot area. |  |
 | Shapes and tools hidden under the Zoom navigator overlay are now not selected when clicking inside the navigator |  |
 | Corrected some wrong references in SPIP Help |  |
 | Corrected the suppressed display of "mouse over" cursors when a poly-line profile is present in an image |  |
 | Corrected .PRF (Taylor Hobson) profile file reader, which scaled certain files a factor of 1000 wrong in Z |   |
 | Corrected PNG export which actually saved in JPG... |   |
 | Restored connection between X axis labels in the height histogram and the image Z axis color scale labels in presence of AOIs. This includes correct correspondance between histogram cursors and color clip markers. Also the histogram color shading is now again in sync with the image colors in presence of AOI´s. |  |
| Extended Fourier Analysis Module |
 | Corrected crash when using Fourier Peak Marker tool |  |
| Batch Processing & Reporting Module |
 | The color scale markers are now not displayed during Batch processing and Active Reporting, yielding nicer report |  |
 | "Window Save All in JPEG" now also saves multi-curve windows. This is only relevant when a batch script is run from QuickLaunch or when pushing "Run" in the Batch dialog while such windows are present (but not selected) |  |
 | The batch item "Window Save All In JPEG" now again also saves the 3D image window |  |
| Filter Module |
 | Removed non-functional outlier menu items from the Filter dialog File menu |  |
| Force Curve Analysis Module |
 | Negative "dissipation" energy in force curves is now reported instead of reporting blank |  |
 | Corrected mismatch in re-use of output image windows (mapping) in Force Volume |  |
|
| SPIP™ v. 6.0.4 (2012-07-04) |
| Basic Module |
 | It is now possible to evaluate SPIP on WMware virtual PCs |  |
 | Implemented support for IV curves in Agilent .ivs files |   |
 | When saving to data files the image file name shown in the image window is now updated accordingly |   |
 | Tool cursors (Measure Shapes, AOI, etc) are now only displayed and are only active active inside and in close proximity to the actual image display portion of 2D image windows |  |
 | Fixed problem on Windows XP, where IM Explorer and File Open would always start in the examples files folder. |   |
 | Corrected parsing of Omicron Matrix files with more than one occurrence of "--" (double dash) in the file name |   |
| Extended Fourier Analysis Module |
 | Corrected potential crash after deleting band filter circle in FFT image window |  |
| Roughness & Hardness Analysis Module |
 | Corrected scaling of the Integrated Area Power Spectral Density (IASPD) graph. The measurement of RMS value between cursors in IASPD is independent of this scaling and is consistent with the RMS (Sq) value of the entire image when the cursors are set at the ends of the curve |  |
| Particle & Pore Analysis Module |
 | Improved accuracy of statistics calculations in the Shape Measurements result spreadsheet. This has the largest effect on Median, Mode and Percentile statistics |  |
 | Fixed crash in related to Convexity and Solidity parameter calculations |  |
 | If Write to File or Database is specified in Preferences for Particle & Pore Analysis, the result file is now only updated when Detect is pushed and not in case of other changes to the Shapes in an image |  |
| Batch Processing & Reporting Module |
 | Fixed non-working cursor position setup in cross section profile setup in Batch scripts |  |
| Filter Module |
 | The Filters are now taking better care of void data:
When filtering images and profiles having void points, with linear filters kernels, the "void gaps" are now filled with interpolated values, such that the filter kernels can perform without respect to the void data. |  |
| Force Curve Analysis Module |
 | Prevented potential crash after group selection of force curves in force volume image and then stretching selection box outside image area. |  |