SPIP™ v. 6.0.14 (2013-05-23)
Basic Module
bulletThe image file format for Park Systems new NX10 and NX20 SPMs has been implementedFile I/ONew Feature
bulletThe LEXT file format for Olympus laser confocal microscpoes has been implementedFile I/ONew Feature
bulletUser defined color scale limits now works as designed resulting in correct image contrastNew Feature
bulletTiff files with non square pixels are now displayed correctly. XY axis units are shown as "arbitrary"File I/OCorrection
bulletFixed occasional incorrect color in the image zoom navigation overlayCorrection
Correlation Averaging Module
bulletFixed crash when attempting to cross correlate two images of different sizeCorrection
Particle & Pore Analysis Module
bulletErroneous scaling of Particle&Pore Analysis histograms has been fixedCorrection
Batch Processing & Reporting Module
bulletCorrect behavior of the Void Pixels Batch item in case the current image has non-nano units is now ensuredCorrection
Force Curve Analysis Module
bulletReverted JPK force curves are now displayed rightFile I/OCorrection
bulletParsing of NanoSurf force volume files have been correctedFile I/OCorrection


SPIP™ v. 6.0.13 (2013-01-21)
Basic Module
bulletResetting color clip markers when using "Crop to AOI", "Copy Data to Main", Dilate, Erode and Void Pixels ClearCorrection
bulletPreventing crash when using "Copy Data to Main"Correction


SPIP™ v. 6.0.12 (2013-01-11)
Basic Module
bulletCorrecting crash when using "Become Main" before use of FourierCorrection


SPIP™ v. 6.0.11 (2013-01-10)
Basic Module
bulletHistograms can now be saved and loaded again, still being displayed as SPIP histogramsNew Feature
bulletExport of histograms to .asc will now produce a file with x values corresponding to bin centers and y values to bin heightsCorrection
bulletFixed failure to read some Asylum force volume map filesFile I/OCorrection
bulletFixed database error occuring sometimes for non administrator users when starting IMExplorerCorrection
bulletNanonis .3ds format: Corrected x,y units. Data unit for second spectroscopy channels is now always voltFile I/OCorrection
Extended Fourier Analysis Module
bulletAvoiding conflicts and potential crash when Fourier output windows are defined as Main windowCorrection
Roughness & Hardness Analysis Module
bulletThe points, Smr1 and Smr2, used for the calulcation of Spk, Svk, and Sk parameters from the Abbott curve are now also reportedNew Feature
3D Visualization Studio Module
bulletAdjusted default View Settings (surface position and rotation) for 3D displayCorrection
Batch Processing & Reporting Module
bulletFixed crash occuring when an ordinary image loaded in a force curve analysis Batch sequenceCorrection
bulletFixed missing calculated unit cell parameters in Active reports in Batch Process sequences containing Calibrate ## itemsCorrection
Force Curve Analysis Module
bulletImplemented support for JPK .jpk-qi-image file format (16 and 32 bit)New Feature
bulletCorrected interpretation of Nanosurf force volume data filesFile I/OCorrection


SPIP™ v. 6.0.10 (2012-11-27)
Basic Module
bulletAdded multi-channel support for Createc files in compressed formatFile I/ONew Feature
bulletImplemented the AFM Workshop format, .wsfFile I/ONew Feature
bulletInterpolating void pixel areas when performing Fourier analysis and Auto Correlation (making use of Fourier)New Feature
bulletModified cursor read out to allow writing outside the curve drawing region and prevent clipped textCorrection
bulletFixed location of Curve Fitting formula to the top of the curve window.Correction
bulletCorrected Color Clip Marker positions for image with z-range less than 1 nmCorrection
Extended Fourier Analysis Module
bulletCorrected "Cursors on Peaks" in Fourier curves to show the most dominant peaks in order of appearanceCorrection
Roughness & Hardness Analysis Module
bulletCorrected calculation of the Surface Bearing Index, SbiCorrection
Batch Processing & Reporting Module
bulletActive reporting is now cropping screen dumps to cover the data windows only.New Feature
bulletCorrected active reporting Best Fit mode for image copies to respect fixed aspect ratiosCorrection
Force Curve Analysis Module
bulletSupporting Force Volume and Force curve data in NanoSurf file formatFile I/ONew Feature
bulletCorrected wrong Max Pull detection in situations where there is a very low push forceCorrection
Plug-In Interface Module
bulletModified File importer plug-in template for VS 2010 to compile in release mode without modificationsCorrection


SPIP™ v. 6.0.9 (2012-10-04)
Basic Module
bulletCorrected error occurring when exiting SPIP on Windows XP computersCorrection


SPIP™ v. 6.0.8 (2012-10-02)
Basic Module
bulletCorrected installation problemsCorrection


SPIP™ v. 6.0.7 (2012-10-01)
Basic Module
bulletAdded parsing of 32 bit jpk image filesFile I/ONew Feature
bulletAdjusted Agilent PicoView reader to handle missing force volume curves at the end of the image.File I/OCorrection
bulletFixed parsing of certain of Agilent (.mi) force curve filesFile I/OCorrection
bulletVeeco/Bruker SSRM curves are now displayed as IV curves and not as force curvesFile I/OCorrection
bulletDe-selection of all Shapes in images now occurs instantly. Before it could take a long time when there were many ShapesCorrection
bulletFixed wrong line number indaction when printing a profile windowCorrection
bulletCorrected status bar cursor position readout, which in special cases displayed the positions in fractions of pixels (in "pixel" mode)Correction
bulletLeft arrow key now again moves histogram cursors linked to the image color scale correctlyCorrection
bulletWhen changing the number of bins in the Properties dialog of image/profile histograms the new histogram is now calculated over the entire Z range of the data set and not just over the displayed range (i.e. the X axis limits of the histogram)Correction
bulletHistograms: Cursors no. 3, 4.. are now initially placed at the allowed discrete positions in histograms and not as before at positions which could be inside a binCorrection
bulletDuplicating an image with a previously applied but closed Inspection Box would generate an Inspection Box in the duplicate image. This behavior has been annihilatedCorrection
bulletFixed issue that cross section profile decorations would remain on the Main image after a "Close All Except Main" operationCorrection
bulletFixed crash in 16 bit color mode. Note: 16 bit color mode is only partially supportedCorrection
bulletFixed crash in autocorralation on images with uneven number of pixels in X or YCorrection
bulletFixed crash in the Calculator if calculation was executed with out any operand datasetsCorrection
bulletSolved various issues with crash when the ribbon had been minimizedCorrection
bulletFixed crash which could occur because the current image view was in maximized modeCorrection
bulletFixed non-responding SPIP when loading very large ascii filesFile I/OCorrection
bulletFixed crash when undoing closing of a profile window and similar operationsFile I/OCorrection
bulletCorrected potential problem, causing the program to slow down when showing MDI windows in maximized mode and resizing the SPIP program windowCorrection
Calibration Module
bulletUnit Cell & Calibration dialog: Typing in the "dx/dy" field does not activate "Apply" anymoreCorrection
bulletCorrecting an image with parameters Cx=0, Cy=0 and dx/xy = 0 is now prevented as the result could lead to crash in other parts of SPIP, e.g. roughness analysisCorrection
Roughness & Hardness Analysis Module
bulletEntering non-numeric values in the Hardness dialog "Tangent Height %" field is now not allowed, as this would lead to a crashCorrection
Particle & Pore Analysis Module
bulletThe Built-In "Simple Threshold - Pore" settings in Particle&Pore Analysis is now actually configured for pores and not as previously for particlesCorrection
Imagemet Explorer Module
bulletFixed non-responding SPIP after browsing a zip file with ImageMet Explorer and then closing ImageMet ExplorerCorrection
Force Curve Analysis Module
bulletForce Curve analysis settings are now read before analyzing force volume images also when the force curve dialog has not been openedCorrection
bulletCorrected Young’s modulus parameter mapping by DMT model on Force Volume imagesCorrection


SPIP™ v. 6.0.6 (2012-08-23)
Basic Module
bulletCorrected potential crash when ribbon is hidden, and closing all windowsCorrection
bulletCorrected synchronization between red histogram cursor and the corresponding color scale clip maker which were off by one bin width in SPIP 6.0.5Correction


SPIP™ v. 6.0.5 (2012-08-22)
Basic Module
bulletAgilent PicoView Force Volume file format (.mi) has been implementedFile I/ONew Feature
bulletImplemented hitherto unsupported variant of the Wyko .OPD file formatFile I/ONew Feature
bullet"Improved Auto Tiling in cases where the SPIP client area is very wide compared to its heightNew Feature
bulletCorrected collapsing Inspection Box on curves when one tries to move the Inspection Box outside the curve plot area.Correction
bulletShapes and tools hidden under the Zoom navigator overlay are now not selected when clicking inside the navigatorCorrection
bulletCorrected some wrong references in SPIP HelpCorrection
bulletCorrected the suppressed display of "mouse over" cursors when a poly-line profile is present in an imageCorrection
bulletCorrected .PRF (Taylor Hobson) profile file reader, which scaled certain files a factor of 1000 wrong in ZFile I/OCorrection
bulletCorrected PNG export which actually saved in JPG...File I/OCorrection
bulletRestored connection between X axis labels in the height histogram and the image Z axis color scale labels in presence of AOIs. This includes correct correspondance between histogram cursors and color clip markers. Also the histogram color shading is now again in sync with the image colors in presence of AOI´s.Correction
Extended Fourier Analysis Module
bulletCorrected crash when using Fourier Peak Marker toolCorrection
Batch Processing & Reporting Module
bulletThe color scale markers are now not displayed during Batch processing and Active Reporting, yielding nicer reportNew Feature
bullet"Window Save All in JPEG" now also saves multi-curve windows. This is only relevant when a batch script is run from QuickLaunch or when pushing "Run" in the Batch dialog while such windows are present (but not selected)New Feature
bulletThe batch item "Window Save All In JPEG" now again also saves the 3D image windowCorrection
Filter Module
bulletRemoved non-functional outlier menu items from the Filter dialog File menuCorrection
Force Curve Analysis Module
bulletNegative "dissipation" energy in force curves is now reported instead of reporting blankCorrection
bulletCorrected mismatch in re-use of output image windows (mapping) in Force VolumeCorrection


SPIP™ v. 6.0.4 (2012-07-04)
Basic Module
bulletIt is now possible to evaluate SPIP on WMware virtual PCsNew Feature
bulletImplemented support for IV curves in Agilent .ivs filesFile I/ONew Feature
bulletWhen saving to data files the image file name shown in the image window is now updated accordinglyFile I/ONew Feature
bulletTool cursors (Measure Shapes, AOI, etc) are now only displayed and are only active active inside and in close proximity to the actual image display portion of 2D image windowsNew Feature
bulletFixed problem on Windows XP, where IM Explorer and File Open would always start in the examples files folder.File I/OCorrection
bulletCorrected parsing of Omicron Matrix files with more than one occurrence of "--" (double dash) in the file nameFile I/OCorrection
Extended Fourier Analysis Module
bulletCorrected potential crash after deleting band filter circle in FFT image windowCorrection
Roughness & Hardness Analysis Module
bulletCorrected scaling of the Integrated Area Power Spectral Density (IASPD) graph. The measurement of RMS value between cursors in IASPD is independent of this scaling and is consistent with the RMS (Sq) value of the entire image when the cursors are set at the ends of the curveCorrection
Particle & Pore Analysis Module
bulletImproved accuracy of statistics calculations in the Shape Measurements result spreadsheet. This has the largest effect on Median, Mode and Percentile statisticsNew Feature
bulletFixed crash in related to Convexity and Solidity parameter calculationsCorrection
bulletIf Write to File or Database is specified in Preferences for Particle & Pore Analysis, the result file is now only updated when Detect is pushed and not in case of other changes to the Shapes in an imageCorrection
Batch Processing & Reporting Module
bulletFixed non-working cursor position setup in cross section profile setup in Batch scriptsCorrection
Filter Module
bulletThe Filters are now taking better care of void data:
When filtering images and profiles having void points, with linear filters kernels, the "void gaps" are now filled with interpolated values, such that the filter kernels can perform without respect to the void data.
Correction
Force Curve Analysis Module
bulletPrevented potential crash after group selection of force curves in force volume image and then stretching selection box outside image area.Correction